Signal Output - Inepro MicroTimer 2400 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Settings
Function P0, Output configuration
By means of this function the relay output can be defined. It is possible to choose between;
-
A signal output, which is active throughout the whole session.
-
A pulse output which is briefly active/generating a pulse in the beginning of the main time and in the
beginning of the post time.
For more details, see "table of connections".
Setting "00": Signal output
Setting "01": Pulse output

Signal output

Relay 1
Relay 2
Pulse output
Relay 1
Relay 2
End of prior time
Start of main time
Start of prior time
Function P1, External drive facility (as for example a PC.)
Setting "00": Starting the MicroTimer happens through a short pulse on the timer button or coin input
(Depending on menu FA)
Setting "01": Starting the MicroTimer happens by an external device. This device controls the maintime. In case
the signal is active, then also the timer is active, unless the set time has ended. Interrupting the active signal will
put the Microtimer in post-time (when enabled). The controls is depending on the setting in menu FA (remote
button print input or coin mechanism input).
Function P2, After start
At the end of a whole session it is possible to allow one extra time of 30 seconds. To obtain this time the Stop
key has to be pressed. This setting provides a solution for machines, which have to be connected for a short
period of time after the programmed time has expired, e.g. to open the electric door of a washing machine.
Setting "00": After start is no programmed
Setting "01": After start is programmed
(ECOS module EM-07)
®
MicroTimer
2400 Version 4.0 05-11-2007
-
www.inepro.com
End of main
time
-
End of post
ti
17