Semiautomatic programming
Using this method, the travel of the leaves (opening and closing stoppers) is programmed automatically, but the
points at which the gates begin to slow down when approaching the stoppers are programmed manually.
PROGRAMMING AND STARTING UP
1 Place DIP1 and DIP2 in "ON" (semi-automatic
programming); DIP3, DIP4, DIP5 and DIP6 in "OFF".
2 Place DIP7 in "ON" for instalations with two motors.
Place DIP7 in "OFF" for instalations with one motor.
3 We recommend placing DIP8 in "ON" (slow down).
4 Press the full opening control (ST1, key or remote
control).
First leaf 2 is closed, followed by leaf 1, both at
slow speed.
5 DL3 lights up intermittently and leaf 1 begins to
open automatically: press ST1 at the point chosen
for the start of deceleration (A1).
6 Leaf 1 closes at the in-ground stop in opening.
7 Leaf 2 will begin to open automatically: press ST1 at
the point chosen for the start of deceleration (A2).
8 Leaf 2 closes at the in-ground stop in opening.
9 Leaf 2 will begin to close automatically: press ST1 at
the point chosen for the start of deceleration (C2).
10 Leaf 2 closes at the in-ground stop in closing.
11 Leaf 1 will begin to close automatically: press ST1 at
the point chosen for the start of deceleration (C1).
12 Leaf 1 closes at the in-ground stop in closing.
49
Control panel ABC2M-009