The automatic measuring devices are not working
The sensor was not in the rest position at switch-on (A 10) and the
pressed to enter the wheel geometric data with the keypad, disabling control of the
automatic sensor.
Return the sensors to the correct position.
➥
The automatic arm laser line does not work (if present)
To replace the battery, proceed as follows:
Remove the four screws in the
➥
lever (A, Fig.32) and then remove the plastic
casing (B, Fig.32)
Pull out the card (C, Fig.32) inside
➥
Replace the battery in the card
➥
with a new CR2450 3V;
Continue to mount the lever in the
➥
opposite direction to disassembly.
CAUTION
Pay attention to the positioning of the cables
inside the lever groove to prevent acciden-
tally damaging the cable while closing the
plastic crankcase.
If the laser line does not work with the new battery, call for technical assistance.
(only the START key if the guard is installed)
the wheel does not spin (the machine does not start)
For machines with guard, check that it is not raised (the message "A Cr" appears).
Lower the wheel guard.
➥
For machines without guard, check that both the START key as well as the key on the side
of the machine have been pressed.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
Repeat the spin, taking care not to disturb the machine while measuring is in pro-
➥
gress.
The machine does not firmly rest on the floor.
Make sure that the floor support is firm
➥
The wheel is not locked correctly.
Tighten the securing ring nut correctly.
➥
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
➥ Repeat the spin, avoiding any unnecessary strain during the acquisition procedure.