8) TROUBLESHOOTING
No. Fault
Plunger discs cannot en-
1
ter the cartridge
The cartridge cannot be
2
removed from the dis-
penser
3
Dispensing is interrupted
Material discharge is in-
4
terrupted
Spraying procedure is in-
5
terrupted
Instruction handbook DPD/DPS
Version 1.2 · 23.6.17
Cause
• Use of cartridges that are not sup-
plied by Sulzer Mixpac
• Cartridge not fully inserted in car-
tridge sleeve
• Incorrect plunger disc
The plunger discs are still in position
inside the cartridge
Compressed-air supply has been in-
terrupted
Material has hardened in the mixer
Atomizing air supply has been inter-
rupted
10 of 14
Remedy
• Check that there is no foreign mat-
ter in the cartridge sleeve.
• Push the cartridge fully down into
the cartridge sleeve.
• Press the red button (19) to fully re-
tract the plunger discs to the back
end-stop (see "Remove the used
cartridges", page 9)
• Check the compressed-air line
• Replace the mixer (see "Fix the mi-
xer onto the cartridge", page 9)
• Check the atomizing air line and the
quick connectors (see "Fix the mixer
onto the cartridge", page 9)