Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DiSPLAy
StArt
PeLLet feeDing
ignitiOn
StArt-uP
burn POt
cLeAning
finAL cLeAning
StAnD-by
cOOLing
WOrK
MODuLAtiOn
StAnD - by
StDby-bLAcK Out
rOOM t
hOff
Anti-freeze
AntiLOcK
76

DiSPLAyS

reASOn
The start phase is in progress
the continuous feeding of the pellets
during the ignition phase is in
progress
The ignition phase is in progress
The start-up phase is in progress
The automatic burn pot cleaning is in
progress
The final cleaning is in progress
Start-up attempt while the stove is still
in cooling mode
The normal operating phase is in
progress, the stove is operating at the
set power
the stove is operating at minimum
Stove off waiting for re-ignition due
to an external thermostat
The stove is cooling after a power cut.
Displays room temperature (in the
models where provided)
Stove off due to water temperature
over set
The anti-freeze function is in progress
as the h2O t° is below the factory set
threshold
The pump anti-locking function is in
progress (only if the stove has been in
Off status for at least 96 hours)
MeAning
Every time the stove displays one of the alarms listed above it will switch-
off automatically.
The alarm can only be released using button 1 when it switch-off has
been completed. The stove can only be switched back on when it
completely cold
The stove will only re-start when the external thermostat will
Once cooling is complete, it will automatically ignite
As soon as the water temperature drops below the set parameters,
the stove will switch back on
the pump is active until the water reaches the pre-set factory
parameter +2°C
the circulator is activated for the amount of time set by the
manufacturer to prevent it from locking
| engLiSh
_
_
_
_
_
-
-
request it
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Frida idroJole idroMarta idro

Tabla de contenido