Operation
9
Discharge
Pressure
PSi (kPa)
10 (69)
15 (103)
20 (138)
25 (172)
30 (207)
35 (241)
40 (276)
45 (310)
50 (345)
Performance
Chart / GPM(LPM)
3410P-
1 HP
3415P-
1-1/2
HP
3420P-
2 HP
Height
Of Pump
Above Water
/ Feet (Meter)
5' (1.5)
10' (3)
15' (4.6)
20' (6.1)
5' (1.5)
10' (3)
15' (4.6)
20' (6.1)
5' (1.5)
10' (3)
15' (4.6)
20' (6.1)
55 (208)
49(185)
48(181)
45(170)
67 (254)
61 (231)
56 (212)
46(174)
69 (261)
64 (242)
65 (246)
62 (235)
5"1 (193)
46 (I 74)
45 (I 70)
44 (I 66)
66 (250)
58 (220)
55 (208)
45 (I 70)
65 (246)
62 (235)
60 (227)
57 (215)
45 (170)
42 (159)
39 (148)
37 (140)
6"1 (231)
56 (212)
54 (204)
44 (166)
59 (223)
56 (2"12)
54 (204)
52 ('197)
38 (144)
35 (132)
32 (121)
29 (110)
55 (208)
52 ('197)
51 (193)
43 (163)
52 (197)
50 (189)
48 (181)
46 (174)
31 ('117)
28 (106)
24 (90)
20 (76)
48 (181)
45 (170)
44 (166)
37 (140)
47 (178)
45 (170)
42 (159)
40 (15"1)
23 (87)
19 (72)
16 (60)
11 (42)
39 (147)
37 (140)
34 (129)
28 (106)
42 (159)
38 (144)
35 (I 32)
32 (12"1)
17 (64)
13 (49)
8 (30)
33 (125)
27 (102)
20 (76)
II (42)
34 (129)
30 (1"13)
27 (102)
23 (87)
18 (68)
14 (53)
8 (30)
25 (95)
18 (68)
13 (49)
10 (38)
14 (53)
7 (26)
All models except 3420P have discharge and suction size of I- I/2" NPT. 3420P has 2" NPT suction and discharge.
Troubleshooting
I I'I'wARNING
]
Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdrk, er BYTHE HANDLE and short capacitor
terminals together. Do not touch metal screwdriver blade or capacitor terminals, if in doubt, consult a qualified electrician.
SYMPTOM
POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
Motor
will
not run
Disconnect
switch
is off
Be sure switch
is on.
Fuse is blown
or circuit
breaker
tripped
Replace
fuse or reset circuit
breaker.
Starting
switch
is defective
DISCONNECT
POWER;
Replace
starting
switch.
Wires
at motor
are loose,
Refer to instructions
on wiring
(Page 7). DISCONNECT
POWER)
check
and
disconnected,
or wired
incorrectly
tighten
all wiring.
Motor
runs hot and
Motor
is Wire d incorrectly
Refe r to instructions
On Wi(ing.
0verloadkicks0ff0r
V0ltage
is too low
C'-ec'<o'tage'-eing
upp'ie"to-otor,
hTsta'_-eavier
iringffwiresizeis
n
i v i
tJ
_
i
u
m
!
Jill
w
t
motor
does not i:un
and only
hums
I
.
t00 small (See Electfica!/Wiring
Chart)_
Motor
runs but no
In new installation:
water
is delivered*
* (Note:
Stop pump;
then check
prinle
before
looking
for
other causes.
Unscrew
priming
plug and see if water
is in prinling
hole).
Pump
in new installation
did
not pick
up prime
through:
I. hTiproper
prinling
2. Air leaks
3. Lealdng
foot valve
or check
valve
4. Pipe size too small
Pump
has lost prime
through:
I. Air leaks
2. Water
level
below
suction
pipe
inlet
Impeller
is plugged
Check
valve
or foot valve
is stuck shut
Pipes are frozen
Foot valve and/or
strainer
are
buried
in sand or mud
I. Re-prime
according
to instructions.
2. Check
all connections
on suction
line, with
soapy water
or
shaving
Cl'ea m.
3. Replace
foot valve or check
valve.
4. Re-pipe
using size of suction
and discharge
ports on pump.
In installation
already
in use:
I. Check
all connections
on suction
line and shaft seal with
soapy water.
2. Lower
suction
line into water
and re-prinle.
If receding
water
level
in well
exceeds
25' (7.6M),
a deep well
pump
is needed.
Clean
impeller.
Replace
check
valve
or foot valve.
Thaw
pipes.
Bury pipes below
frost
line. Heat
pit or puc0p house.
Raise foot valve
and/or
strainer
above
bottom
of water
source.
Clean
foot valve and strainec
*Pump
does not
Water
leve!
in Wel! is lower
tl_0n
R deep
Well jet wilt
be needed
if your
well
is more
than 25' (7_6M)
deliver
water
t0 ful!
estimated
depth
to water .
capac ty
<-
Steel
_iping
(if used) is corroded
or
Replace
with
Piastic
Pipe where
possible,
otherwise
with
new Steel pipe.
limed,
causing
excess
fricti0n
Piping
is tOO smalt
in size
Re-pipe
using
size o{ suction
and discl_arge
p01_s 0n pump_
Pump
not being
supplied
wit h
Add
additiona
I well
p0ints_
enough
water
Pump
leaks
Clamp
loose
STOP PUMP, tighten
clamp
nut 1-2 turns. Alternately
tighten
and tap on
around
clamp
clamp
with
nlallet
to seat O-Ring.
Do not overtighten.
I
For parts or assistanCe'call Simer customer service at
1..800;468,7867 ! 1-800,546..7867
I