12.4

Workplace requirements

The KAP 255XJL sliding compound saw has to be attached to the underground. For this purpose
there are 4 borings at the ground plate, two at the front side, two at the back side.
Furthermore you can attach the machine to compound saw stands.
Operating a non attached saw poses a security risk!
12.5

Electric information

Connect the KAP 255 XJL only to a power supply with fuse.
Power socket must be fused as well.
 The connection of the machine to the electric power supply and the following checks are to be
carried out by respectively trained personnel.
 The electronic connection of the machine is designated for operation with a grounded power
socket!
 The connector plug may not be manipulated.
 If the connector plug doesn't fit or if it is defect, only qualified electricians might modify or re-
new it!
 The grounding wire should be held in green-yellow.
 A damaged cable has to be exchanged immediately!
 Check, whether the feeding voltage and the Hz comply to the required values of the machine.
A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working voltage of
380V can work within a voltage bandwidth of 370 till 400V.
 To determine the required diameter of the feeding cable, take the spreadsheet as a reference.