AUtec Modular Serie Manual De Usuario página 36

Ocultar thumbs Ver también para Modular Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

LIMKDPU0
MK10 DF TRANSCEIVING UNIT DIAGNOSTICS
If only the display or the visualisation LEDs do not work, refer to the procedure on the
next page. If the "machine+radio remote control" system does not start, check if the
problem is caused by the radio remote control or the machine. Before carrying out any
verifications, check the functioning of the machine with the cable control panel:
- if it does not switch on, the problem lies with the machine itself
- if it does switch on, the problem lies with the radio remote control. In this case, proceed as
follows:
When START is
activated, is the red
LED lit steadily
and does the buzzer
sound?
NO
Does the red LED
blink and does
the buzzer sound?
NO
Does the green LED
blink?
NO
If the problem
persists
CALL
TECHNICAL
ASSISTANCE
TRANSMITTING UNIT DIAGNOSTICS
Is the STOP
button or one
YES
of the movement
actuator inserted?
Release it/them
The battery is
discharged:
replace it with one
YES
that is charged.
Does the LED
continue flashing
and the buzzer
sounding?
NO
Carry out
YES
diagnostics
checks on the
receiving unit.
10
YES
Is the led on with
a steady light?
NO
Clean the contacts
in the battery seat.
Does the LED
continue flashing
and the buzzer
sounding?
NO
YES
YES
Page 16

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para: