8.1

Troubleshooting guide

Problem
The ON/OFF switch is in
position 1, but the green led
(power) does not light up.
The power source is on, but the
yellow AIR PRESSURE led
remains lit.
The power source is on, but the
yellow OVER TEMPERATURE
led remains lit.
The power source is on, the
orange FAULT led remains lit.
The power source is on, the
yellow PIP led remains lit.
The thermal switch trips during
cutting.
The arc does not strike or the
arc disappears during cutting.
bp23aa
Cause
S
There is no power present.
S
Tripped circuit breaker
S
The air pressure is low.
S
No air is present
S
The power source is still
overheated. It will cool
down sooner with the fan
on.
S
The thermal switch is
faulty.
S
The power source is not
enabled. A safety switch,
cover, has been activated.
S
There is a parts-in-place
error.
S
The power required by the
power source has
exceeded the power
available from the incoming
line voltage.
S
Another appplicance is
working on the same line.
S
The wear parts of the torch
are worn.
S
The power module is
overheated.
S
There is not sufficient air
pressure.
S
There is low voltage on the
incoming line.
- 23 -
Solution
S
Check the power supply.
S
Check the breaker.
S
Increase the air pressure.
S
Check if air is supplied.
S
Switch on the power
source and wait a few
minutes before working
again.
S
Call authorized service
technicians.
S
Check if the consumables
are in place and properly
tightened.
S
Check that the side panel
has been correctly closed
(torch connector inspection
side).
S
Check if the consumables
are in place and properly
tightened.
S
Reduce the cutting current
with the command on the
front panel or reduce the
cutting time.
S
Reduce the length of the
connecting cable or
increase the cable section.
S
Do not connect other
appliances to the same
line.
S
Check the torch and fit
spare parts if necessary.
S
See if the yellow OVER
TEMPERATURE led on
the front panel is lit. Wait
until the power source
cools down.
S
See if the yellow AIR
PRESSURE led on the
front panel is lit. Increase
the air pressure.
S
Check the incoming line. If
an extension is being used,
ensure that the cable
section is adequate.