Prior to installation, read these installation
and operating instructions. Installation and
operation must comply with local regula-
tions and accepted codes of good prac-
tice.

1. General description

With float switch
Fig. 1
1. Discharge port 1.25" NPT.
2. Handle.
3. Clamp.
4. Suction strainer.
5. Outer casing.
6. Float switch (optional).

1.1 Applications

The Grundfos Unilift KP 150, KP 250 and KP 350
pumps are single-stage submersible pumps
designed for pumping grey water.
CAUTION: This pump has been evaluated for use
with water, grey wastewater and heated wastewater.
4
The pump is capable of pumping water which con-
tains a limited quantity of spherical solids up to 3/8"
Page
in diameter without being blocked or damaged.
4
The pump is suitable for automatic (with float switch)
4
as well as manual operation and can be installed in a
4
permanent installation or used as a portable pump.
5
The pump is suitable for:
5
• Drainage of basements or buildings prone to
5
flooding,
5
• Pumping of wastewater from washing machines,
5
sinks, baths, showers, etc., up to the sewer level,
5
• Dewatering of sites or the pumping of water for
6
fountains,
6
6
• Pumping in draining wells,
6
• Emptying swimming pools, ponds, tanks, or foun-
6
tains.
6
7
Do not use the pump in or at swimming
8
pools, garden ponds, etc. when there are
persons in the water.
8
The pump is not suitable for pumping:
• sewage
• liquids containing long fibers
• liquids containing solid particles larger than 3/8" in
diameter
• flammable liquids (oil, gasoline, etc.)
• aggressive liquids.
Note: If the pump has been used for very dirty or
chlorinated water it should be flushed thoroughly
with clean water after use.
The pump contains approx. 70 ml of non-poisonous
motor liquid that may pollute the pumped liquid if the
pump should leak.

1.2 Operating conditions

Liquid temperature
Minimum 32°F. The maximum liquid temperature
depends on the rated voltage of the pump, see the
table below.
Voltage
1 x 115 V, 60 Hz
At intervals of at least 30 minutes, the pump is
allowed, however, to run at maximum +158°F for
periods not exceeding 2 minutes.
Storage temperature
Not lower than -4°F.
Minimum water level
Water level must be above strainer inlet.
Maximum installation depth
30 feet below liquid level.
Maximum
liquid temperature
+122°F (+113°F KP 350)