INSP
ADJ
CONTROL SYSTEM
QSTS cable inspection and adjustment
1. Measure:
Nozzle deflector set length a, b
Difference → Adjust.
Measurement steps:
Set the control grip in the neutral posi-
tion.
Measure
the
length a and b.
If a and b length are not even, adjust
the cable joint.
2. Adjust:
QSTS cable
Adjustment steps:
Set the control grip in the neutral posi-
tion.
Loosen the locknut 1.
Remove the nut 2 and pivot pin 3.
Set the jet nozzle in the center posi-
tion.
Turn the cable joint 4 for adjusting.
Turn in
Turn out
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
Connect the cable joint 4 and pivot
pin 3 and tighten the nut 2.
Nut:
4 Nm (0.4 m • kgf, 2.9 ft • lb)
Tighten the locknut 1.
Locknut:
4 Nm (0.4 m • kgf, 2.9 ft • lb)
3-5
nozzle
deflector
Length b is increased.
Length a is increased.
E
set