Operational Features; Safety Tips - Toyotomi TAD-T40LW Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SUMMARY
The idea behind the unit is to provide a localized supply of cool air.
The unit will greatly enhance your personal comfort whether at a
work station or even in your favorite chair.
Four (4) casters enable you to move the unit easily from room to
room. It cools and dries the air at the same time so that you can
stay comfortable even when it's humid or rainy outside. Also your
furnishings and fabrics are kept in good condition when it's used
as dehumidifier.
Conventional air conditioners use large quantities of energy to cool
an entire room, including walls and furniture. This unit creates a
zone of cool and dry air only where it is needed. It does not waste
energy cooling the surroundings.
It's easy to operate. The built-in timer allows from 1 to 24 hours of
operation, which will automatically turn the unit on and off. This is
especially convenient at bedtime.
Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by us-
ing the venting kit accessory, which is included with the uit.

OPERATIONAL FEATURES

1.
COOLING OPERATION:
Normally, cool air is directed out the front louvers by the circu-
lation fan which has three (3) stages of fan speed.
2.
HEATING OPERATION:
Warm air is directed out the air outlet grille by the circulation
fan which has three (3) stages of fan speed.
3.
THERMO CONTROL
The compressor will automatically shift to ON or OFF to main-
tain the desired temperature.
4.
TIMER OPERATION:
The unit will turn on and off after the designated period of time
(1, 2, 3, ...24 hours).
5.
AUTOMATIC SHUT-OFF MECHANISM WHEN THE
DRAIN TANK IS FULL:
When the drain tank is full, the unit will be automatically shut
off. The warning lamp will light. It is always required to press
the power button twice to resume operation after the con-
densed water is removed from the tank.
6.
AIR FILTER:
A pre-filter protects the unit from dust.
1. DESCRIPTION
Fig. A
FRONT
A1
Air outlet
A2
Vertical louver
A3
Front panel
A4
Operation panel
A5
Carrying handle
A6
Caster
Fig. B
REAR
B1
Air intake (Evaporator)
B2
Air intake opening
B3
Air intake (Condenser)
B4
Power supply cord
B5
Power plug
B6
Drain water outlet
B7
Air outlet opening
Fig. C
OPERATION PANEL
C1
Power button
C2
Mode button
C3
Fan speed button
C4
Timer button
C5
Adjust buttons
C6
Warning lamp (Tank full)
C7
Cooling mode lamp (green)
C8
Dehumidifying mode lamp (orange)
C9
Heating/Fan mode lamp (red/yellow)
C10 Room temp lamp
C11 Set temp lamp
C12 Timer operation lamp
C13 Digital indicator
Fig. I
DUCT SET
I1
Duct hose adapter nozzle (4 pcs.)
I2
Duct hose (2 pcs.)
Fig. J
WINDOW PANEL KIT
J1
Window panel "C"
J2
Window panel extension (2 pcs.)
J3
Duct hose grille (2 pcs.)
J4
Cover (2 pcs.)
J5
Screws

2. SAFETY TIPS

IMPORTANT
¡ Read instructions carefully before operation.
¡ The unit should be operated when the room temperature is
between 64˚F (18˚C) to 95˚F (35˚C). If the room temperature is
below 64˚F (18˚C), ice may form on the coils. If the room tem-
perature is above 95˚F (35˚C), the compressor will automatical-
ly shut off to protect itself.
¡ ALWAYS, wait 3 min. to restart after turning unit off.
WARNING
¡ NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.
¡ Keep children away from unit. Children are particularly liable to
this danger. The inside fan is running at high speed. Covering
them may deteriorate air conditioner performance or cause it
to become inoperative.
¡ NEVER insert objects of any kind into the air intake or air out-
let.
¡ DO NOT unplug if your hands are wet. An electrical shock may
occur.
¡ DO NOT operate in a wet location.
¡ ALWAYS plug into 115 V, 60 Hz, single phase electrical outlet.
¡ Be sure the power plug fits the receptacle securely.
¡ DO NOT run power cord under carpets, rugs, or floor mats of
any kind.
¡ DO NOT attempt to shorten or alter power cord in any way.
¡ DO NOT apply any excessive force or pressure to the power
supply cord.
¡ Make sure that the plug is free of dust.
¡ DO NOT use an extension cord.
¡ DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.
¡ If there is a fear of lightning, stop the unit and disconnect the
power supply cord.
¡ DO NOT touch the evaporator, condenser and pipes.
¡ DO NOT operate with filter removed.
CAUTION
¡ Keep unit more than 20 in. (50 cm) away from any objects or
wall. (Fig. D)
¡ If the unit is operated in COOLING mode in an area of very
high moisture, the top plate and the rear plate may get cov-
ered with a mist. Wipe off any mist before it has a chance to
get on the floor or rug.
¡ Remove drain water before moving unit.
¡ To minimize corrosion, DO NOT use in damp, salty air area.
¡ DO NOT operate in direct sunlight.
¡ DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.
¡ DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.
¡ DO NOT ride or place the objects on the unit.
¡ DO NOT turn the unit on its side or upside down.
1
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido