Disconnecting the high-pressure hose
3
1
Unroll the high-pressure hose (1)
N
Open the hose guide (2)
N
Unscrew the union nut (3).
N
Pull high-pressure hose (1) off of
N
connector
Connecting the high-pressure hose
Push the high-pressure hose (1)
N
onto the connector of the hose reel
Attach union nut (3) and screw it on
N
and tighten by hand
Push the high-pressure hose into
N
the hose guide (2) and close the
hose guide.
Roll up high-pressure hose
N
RE 362, RE 362 PLUS, RE 462, RE 462 PLUS
High-pressure hose and spray gun
Fitting
2
3
1
Push the high-pressure hose (1)
N
onto the connector (2)
Attach union nut (3) and screw it on
N
and tighten by hand
Removing
4
3
Push the coupling (4) in the
N
direction of the arrow and hold it
Loosen the union nut (3) and
N
unscrew it from the connector in the
direction of the arrow
High-pressure hose extension
As a rule, always use only one high-
pressure hose extension – see "Special
accessories"

Connecting the water supply

Briefly rinse out the water hose before
connecting it to the machine to prevent
sand and other particles from entering
the machine.
Connect hose ( 3/4" diameter,
N
length at least 10 m to absorb
pressure surges)
Mesh the jaws with each other and
N
turn right as far as possible
Turn on water supply
N
To vent the system:
Actuate the spray gun (without
N
spray lance mounted) until a
uniform water jet emerges
In suction operation, the machine can
also be connected to rivers, lakes,
cisterns and tanks, etc. – see
"Connecting to a pressureless water
supply".
English