TIMER
The timer allows you to set a time for automatic shutdown, this time can vary
from 1 minute to 3 hours. For the timer setting you must first select an
operating mode (power or temperature) and a power level or temperature
respectively.
For the timer setting, follow these steps:
1. With the plate turned on and a pan in the cooking zone, choose an
operating mode and a power or temperature level.
2. Momentarily touch the button 2 ( F ) with the tip of your finger, the display
will show the indication " 0 " and the LED indicator of the timer mode 7
flashing.
3. Touch the touch pad 4 () or 5 () with your fingertip to increase or
decrease the time in 1 minute jumps respectively, if you touch and keep the
touch of the finger on these buttons, the jumps will be 10 minutes. Screen 3
will show the time in minutes.
4. Once the time has been selected, screen 3 will alternately show the
selected power or temperature and the remaining time for automatic
shutdown. The LED indicator of timer mode 8 will remain lit to let you know
that the timer is activated.
5. During cooking you can increase or decrease the power or temperature,
using the 4 () or 5 () buttons.
6. To cancel the timer, touch the button 2 ( F ) with your fingertip and choose
an operating mode and a power or temperature level again, the timer mode
LED indicator 8 will turn off.
Note:
If activating the timer (display " 0 " flashing) within 5 seconds to select the
time for shutdown, timer mode is automatically deactivated.

CONTROL PANEL LOCK

The induction plate incorporates a blocking device, which deactivates the
operation of the function selection button ( F ) and the increase () and
decrease () buttons of the power and / or temperature.
The blocking of the control panel prevents the induction plate from being turned
on by mistake or by mistake (if the plate is switched off), or the power or the
chosen temperature is changed (if the plate is in operation).
To lock the control panel, press both buttons 10 (MAX) and 9 (MIN) at the
same time. When the control panel is locked, screen 3 show the indication " L ".