FUNCTIONS OF SWITCHES ON ELECTRONIC BOARD
1 - Opening / closing speed:
ON = SLOW OPENING / CLOSING
2 - Type of door:
ON =SINGLE DOOR > 50 KG OR DOUBLE DOOR
3 - Door lock:
ON = ACTIVE LOCK
4 – rotation way:
ON = STANDARD ROTATION WAY
5 - Auto-close function:
ON = ACTIVE FUNCTION
6 - Sensitivity to obstacles:
ON = STANDARD SENSITIVITY
SET UP PROCEDURES
Available functions on electronic board are:
•
self-learning
•
recording of a radio switch command code (if utilised)
•
erasing of a radio switch command code (if utilised)
SELF-LEARNING
IMPORTANT: ensure that any eventual optional device is disconnected. Do not record any radio
switch command code before self-learning procedure is successfully completed.
1 -
Place the door 10 to15 cm far from the closed position
2 -
Press the push button on electronic board for about 5 seconds, until the green led blinks rapidly and then turns
off; the door starts moving between the stop positions; 4 cycles after, the self-learning procedure is complete.
NOTA: at the end of the self-learning procedure, the door may be either opened or closed, according to the side
position of the motor with respect to the door itself.
HOW TO RECORD A RADIO SWITCH COMMAND CODE IN THE ELECTRONIC BOARD MEMORY
IMPORTANT: ensure that any eventual optional device is disconnected. Do not record any radio
switch command code before self-learning procedure is successfully completed.
1 -
Make one single short pressing (<1 sec) on the push button on electronic board; the green led lightens steady.
2 -
Press the two buttons on the radio switch command simultaneously; the green led blinks rapidly and then
turns off, to confi rm the recording of the code.
IMPORTANT : to swap directions on buttons, change the position of switch n°4 on the electronic board.
HOW TO ERASE A RADIO SWITCH COMMAND CODE IN THE ELECTRONIC BOARD MEMORY
1 -
Make two single short pressing (<1 sec) on the push button on electronic board; the green led blinks slowly.
2 -
Press the two buttons on the radio switch command simultaneously; the green led blinks rapidly and then
turns off, to confi rm the erasing of the code.
NOTA: if no radio command code is recorded in the electronic board memory, the red LED will blink 5 times every
3 seconds.
For the other available settings, which are not mensioned in the PROGRAMMING INSTRUCTION section,
please refer to the « Functions of switches ».
NM 10206 D
NM 10206 D
NM 10206 D
C
A
A
01-2014
10-11
10-11
MANTION SAS
MANTION SAS
MANTION SAS
- 25000 Besançon - Tel +33 3 81 50 56 77 - Fax +33 3 8185 38 79 - www.mantion.com
- 25000 Besançon - Tel +33 3 81 50 56 77 - Fax +33 3 8185 38 79 - www.mantion.com
- 25000 Besançon - Tel +33 3 81 50 56 77 - Fax +33 3 8185 38 79 - www.mantion.com
OFF = QUICK OPENING / CLOSING
OFF = SINGLE DOOR < 50 KG
OFF = INACTIVE LOCK
OFF = OPPOSITE ROTATION WAY
OFF = INACTIVE FUNCTION
OFF = LOW SENSITIVITY
red LED
green LED
BP
16/20
13/16
18/20