Descargar Imprimir esta página

Pentair intellicomm Automation Guia De Instalacion página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
7
The IntelliComm provides four pairs of input terminals which can be actuated by either 15 to 240
VAC or 15 to 100 VDC from the source device, (automation controller, heater, heat pump etc.).
There are four IntelliFlo external control programs that can be enabled.
Note: The IntelliComm will always be configured to communicate to pump address 1.
IntelliComm system wiring table
Terminal number
Terminal name
1-2
Power supply
3-4
5-6
7-8
9-10
11
+ Data: Yellow
12
- Data: Green
Note: (*) indicates current controlled input, voltage independent.
Power Requirements: The IntelliComm draws less than 1 amp. Over current protection of
the wires connecting the source device, (automation controller, heater, heat pump etc.) to the
IntelliComm must be provided at the source.
Inputs from remote device: The IntelliComm has four current sensing inputs that are activated by either
15 VAC to 240 VAC or 15 VDC to 100 VDC.
Output to IntelliFlo pumps: The IntelliComm communicates with IntelliFlo pumps via a two wire
RS-485 Serial link.
Voltage
100 - 240 VAC
15 -240 VAC
Program 1
or
15 - 100 VDC
15 -240 VAC
Program 2
or
15 - 100 VDC
15 -240 VAC
Program 3
or
15 - 100 VDC
15 -240 VAC
Program 4
or
15 - 100 VDC
RS-485
-5 to +5 VDC
Ground
IntelliComm electrical specifications
IntelliComm system wiring
Maximum current
Phase type
100 mA
1 Input
1 mA*
1 Input
1 mA*
1 Input
1 mA*
1 Input
1 mA*
1 Input
5 mA
1 Output
Section 7
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
N/A
Section 8

Publicidad

loading