Sunea io
8.3. Restoring the original configuration
This reset deletes all the control points, all the sensors, all the end limits settings and resets the
motor's direction of rotation and favourite position (my). However, the advanced functions setting
("Back impulse", "Back release", "Closing force") are kept.
Apply the double power cut only for the motor to be reset!
1)
Set the awning to the halfway position (if possible).
2)
Cut the power supply off for 2 seconds.
3)
Switch the power supply back on from 5 to 15 seconds.
4)
Cut the power supply off for 2 seconds.
5)
Switch the power supply back on: the awning makes a
movement for several seconds.
If the awning is in the upper or lower end limit position
it will make a brief movement.
6)
Press and hold the PROG button: the awning will make
a first movement, and repeat it a few moments later. The
motor is configured with the factory settings.
-
Repeat the procedures in the chapter "
9. TECHNICAL DATA
Radio frequency
Power supply
Operating temperature
Protection rating
Maximum number of connected io control
points and io sensors
Safety level
10
1
3
5
Commissioning".
6
868-870 Mhz, io-homecontrol® triband bi-directional
- 20 °C to + 70 °C
Copyright © 2010 Somfy SAS. All rights reserved.
2
5 sec
4
ON
15 sec
ON
230 V ~ 50 Hz
IP 44
9
Category I
OFF
2 sec
OFF
2 sec
my