6.3.2 Warning messages

Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO contact remains
closed), are indicated in the LED display on the front panel by a coded warning number.
Number Designation
E/S/A/P Status Messages
. . .
Status Message
-
Status Message
n01
I²t
n02
Brake power
n03
S_fault
n04
Response monitoring
n05
Supply phase
n06
SW limit switch 1
n07
SW limit switch 2
n08
Motion task error
n09
No reference point
n10
PSTOP
n11
NSTOP
Motor default values
n12
loaded
n13
Slot warning
n14
SinCos feedback
n15
Table error
n16
Summarized warning
n17
Fielbus Synchronization
n18
Multiturn overrun
n19
Motion task ramps are limited Range overflow on motion task data
n20
Wrong GMT data
n21
PLC program error
max. motor temperatur
n22
reached
n23...n31 reserved
n32
firmware beta version
More information to the messages can be found in the ASCII Object Reference
STATCODE. Hints for removal can be found in section "Trouble-Shooting" of the online help.
Explanation
Status messages, no error, see p.
Updating the startup configuration
Programming mode
I²t threshold exceeded
Reached preset electrical brake power limit
Exceeded preset following error limit
Response monitoring (fieldbus) has been activated
Mains supply phase missing
Underrun software limit switch 1
Overrun software limit switch 2
A faulty motion task was started
No reference point (Home) set at start of motion task
PSTOP limit-switch activated
NSTOP limit-switch activated
Only for ENDAT or HIPERFACE
ber saved in the encoder and the amplifier, motor default values loaded
24V supply of the I/O expansion board is missing
SinCos commutation (wake & shake) not completed, will be can-
celed when amplifier is enabled and wake & shake carried out
Fault according to speed/current table INXMODE 35
Summarized warning for n17 to n31
The mode synchronization SYNCSRC is selected but the drive isn't
in synchronies cycle
Using Multiturn encoder feedback, an overrun over the maximum
number of resolutions was detected
Wrong "Graphical Motion Task" data
For details see plc code
The user can shut down the process before the temperature eror will
interrupt the process immediately
reserved
Firmware is an unreleased beta version
Kollmorgen | wiki-kollmorgen.eu | April 2016
S600 Safety Guide | 6   Appendix
® :discrepancy between motor num-
(online help
), see parameter
183