2.3 Handling

2.3.1 Transport

Transport the SERVOSTAR 600 in accordance with IEC 61800-2 as follows:
Only by qualified personnel in the manufacturer's original recyclable packaging
Avoid shocks
Temperature: –25 to +70°C, max. 20K/hr rate of change
Humidity: max. 95% relative humidity, no condensation
If the packaging is damaged, check the unit for visible damage. In this case, inform the
shipper and the manufacturer.
The servo amplifiers contain electrostatically sensitive components which can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid contact
with highly insulating materials (artificial fabrics, plastic films etc.). Place the servo amplifier
on a conductive surface.

2.3.2 Packaging

The SERVOSTAR 600 packaging consists of recyclable cardboard with inserts.
Dimensions:
SERVOSTAR 601-610(HxWxD): 125x415x350 mm
SERVOSTAR 614/620(HxWxD): 170x415x350 mm
SERVOSTAR 640/670(HxWxD): 410x470x490 mm
Labeling : nameplate outside at the box

2.3.3 Storage

Store the SERVOSTAR 600 in accordance with IEC 61800-2 as follows:
Storage only in the manufacturer's original recyclable packaging
Max. stacking height SERVOSTAR 601-620: 8 cartons
Max. stacking height SERVOSTAR 640-670: 3 cartons
Storage temperature: -25 to +55°C, max. rate of change 20°C / hour
Storage humidity: 5 ... 95% relative humidity, no condensation
Storage duration: Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC
for about 30 minutes to the terminals L1 / L2.

2.3.4 Decommissioning

Only professional staff who are qualified in electrical engineering are allowed to decom-
mission parts of the drive system.
DANGER
There is a danger of serious personal injury or death by electrical shock or electrical arcing.
Switch off the main switch of the switchgear cabinet.
Secure the system against restarting.
Block the main switch.
Wait at least 5 minutes after disconnecting.
: Lethal voltages!
S600 Safety Guide | 2   English
Kollmorgen | wiki-kollmorgen.eu | April 2016