e. Charging Process
Charging Status
Standby (Self-examine lights red
1second when power on)
Charging
(Charge in a constant current)
Fully charged
(Charge in a constant voltage)
f. LED Indicator:
Self-Test When Power on
No Battery
Charge Normally
Fully Charged
Trouble
» Trouble means battery too warm, battery short-circuited or
charger short-circuited.

Normal Charging Tips

2.5
a.
Self-Test: When powering on the charger, the red light turns on and then
turns off and stays off, which means the charger has passed it self- test
and it is ready to charge the battery. If the light remains orange or the
red light blinks, it means the charger cannot pass it self-test and cannot
charge the battery.
b.
Trickle Pre-Charging: If red light blinks when the battery is inserted
into the charger, it means that the battery voltage is low and the charger
is trickle-charging the battery (Pre-Charging Mode). The charger will
automatically turn into normal charging when the battery reaches a
certain electric charge, and if the red light stops blinking, it means the
battery voltage has reached a certain level, and the charger will charge
the battery in normal mode.
5
2. BATTERY INFORMATION
STATUS
AT-D878UV Digital DMR and Analog UHF/VHF Two Way Radio
Indicator Status
None
Lights red for about 3 hours
Lights green
LED
Red (for 1 second)
Green
Red
Green
Red blinks fast for a long time