FEC
2.8 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
Further measures can be found in the power source operating instructions or in the documentation for other
peripheral devices.
3 Product description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorization.
• The device may be used only by qualified personnel (in Germany, see TRBS 1203).
3.1 Technical data
Connection voltage
Drive power
Mains frequency
Filter surface
Connection diameter
Max. vacuum
Max. air volume flow
Average sound pressure level LpA
Weight
Dimensions (LxWxH)
Tab. 1
General information
1Measured according to the enveloping surface method according to DIN EN ISO 3744, measured at minimum
volume flow; uncertainty of measurement of noise approx. ±4 (dB)A
Ambient temperature
Relative humidity
Tab. 2
Ambient conditions during operation
Storage in a closed environment, ambient temperature
Ambient temperature for shipment
Relative humidity
Tab. 3
Ambient conditions for transport and storage
3.2 Abbreviations
FEC
Tab. 4
Abbreviations and term definitions
BAL.0533.0 • 2018-10-04
115 V
50 Hz/60 Hz
1
Fume extraction system (Fume Extraction Cyclone)
3 Product description
230 V
1.1 kW
50 Hz
2
0.8 m
50 mm
19,000 Pa
230 m³/h
76 dB(A)
25 kg
590 × 425 × 825
0 °C to +40 °C
Up to 90 % at 20 °C
0 °C to +40 °C
−15 °C to +40 °C
Up to 90 % at 20 °C
EN - 7