Technical Data; Safety Devices; Warning Symbols; Connection To The Extension Pole - CAMPAGNOLA MA 100 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.6

Technical data

MA 100
Operating pressure:
Air comsumption:
Weight (gr.):
Connection to extension pole:
MA 120
Operating pressure:
Air comsumption:
Weight (gr.):
Connection to extension pole:
3.7

Safety devices

Active safety device (23): is inserted automatically when releasing the operating lever (24) and prevents the tool from
starting accidentally.
Handle (22) guard: ensures that the lever (24) is not operated accidentally.
3.8

Warning symbols

General warning
Duty of reading the use &
maintenance manual
Compulsory head protection
4.1

Connection to the extension pole

Mount the extension pole (35) or (36) onto the tool (turn it clockwise). Screw it on the connection (12) until it is secured
in place. Turn it counter-clockwise to disassemble it.
Make sure that the air filter (27) located on the fitting (26) is clean and correctly installed.
NOTE!
Disconnect the tool from the air supply hose before carrying out this operation.
4.2

Connection to the air supply

Make sure that the safety catch (23) is
Check the filter and clean it if necessary.
Connect the supply hose to the fitting (26) having first made sure that the fitting (26) is thoroughly clean. The inside
diameter must be at least 6 mm.
WARNING!
Just use compressors or pneumatic equipment complying with the current laws and fitted with a maximum safety
valve.
NOTE!
Make sure that the air hose is in perfect condition. It should not be bent or damaged in any way.
Adjust the air lubricator fitted on the compressor so that a drop falls every 10 seconds.
When necessary, add the kind of oil recommended by the Manufacturer.
4.3

Control devices

To start the harvester, the safety catch (23) must be kept in its forward position. Press the control lever (24).
To stop the tool, release the control lever (24).
Use and Maintenance Manual – Original
Instructions Rev.: 00, Date 21/06/2019
7 bar (700 kPa)
200 l/min.
1.000
yes
6 bar (600 kPa)
150 l/min.
1.000
yes
engaged.
Compulsory adequate clothing
Compulsory hands protection
Compulsory feet protection
Pag. 21