General Maintenance - Vulcan 650-4815 Manual De Instrucciones

Compressor de aire de 28 galones
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.
Through the oil fill hole, refill the reservoir with SAE-20 or SAE-30 (API CG/CD
heavy duty), non-detergent compressor oil. For extreme winter conditions, use
SAE-10 weight
4.
Fill to the red dot in the oil level sight glass. Do not over-fill.
5.
Replace the oil fill plug.
CAUTION
!
l All air line components (including hoses, pipe, connectors, filters, & regulators,
etc.) must be rated for a minimum working pressure of 150 psi or 150% of the
maximum system pressure, whichever is greater.
l Disconnect any tools from the air supply before performing maintenance,
clearing a jammed fastener, leaving the work area, moving the tool to another
location, or handing it to another person.
l When cleaning air filter, or any parts in direct contact with the air production, do
not use any flammable or toxic cleaner or solvent.
l During the break-in period, nuts and bolts have a tendency to loosen up. After
two weeks, tighten all nuts and bolts including head bolts.

GENERAL MAINTENANCE

l Keep the vents and cooling vanes clear of dust and debris. This will help
prevent possible electrical shorts and ensure proper cooling.
l Inspect the cord regularly and have it replaced by an authorized repair facility if
it is damaged.
l Check the tanks regularly for dents, cracks, rust, and other damage. Do not use
if any part of the pressurized system is damaged.
l An authorized repair center should do any repairs, modification, or maintenance
that involve disassembling the compressor.
l Please call toll-free 1-800-482-0131 with any questions you have or service
advice you may need.