DMX-protocol
Control channel 1 – Red
DMX-value
Feature
0-255
(0=white, 255=red)
Control channel 2 – Green
DMX-value
Feature
0-255
(0=white, 255=green)
Control channel 3 – Blue
DMX-value
Feature
0-255
(0=white, 255=blue)
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lenses have to be replaced when they are obviously damaged,
so that their function is impaired, e. g. due to cracks or deep scratches!
The lenses will require weekly cleaning as smoke-fluid tends to building up residues, reducing the light-
output very quickly. The cooling-fan should be cleaned monthly.
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service
operations are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!
24/47