Descargar Imprimir esta página

Installation - La Nordica WIND AIR Manual De Instrucciones

Ocultar thumbs Ver también para WIND AIR:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTALLATION

Through installation of the WIND-AIR Kit it is possible to distribute the hot air through the adjacent rooms.
for efficient functioning of the appliance, sufficient air for the combustion and re-oxygenation of the environment must be
supplied in the place of installation. This means that, through appropriate openings connected with the outside, it must be possible
to circulate air for combustion even when doors and windows are closed (See USER MANUAL of the product).
THIS OPERATION MUST ALWAYS BE PERFORMED IN THE ABSENCE OF ELECTRICAL POWER SUPPLY !!
The ignition and the regulation is carried out through the
appropriate regulator supplied which must be installed far away
from direct heat sources.
ATTENTION: the regulator and the power cord must
NOT be in contact with hot parts.
The outlets must be positioned at a height of no less than 2 m from
the floor to prevent the outgoing hot air from striking persons;
respect the distance of the convention openings according to
local building regulations;
The upper part of the cover of each product is fitted with
outputs for connection of the air ducting pipes:
- if present, remove the sheet metal perforated panels A from the
outlets at which the air ducting pipes are to be connected;
Each pipe must not exceed 8 meters for forced ventilation,
it must be insulated with insulating materials to avoid noise
and heat dispersion.
The lengths of the ducting pipes should possibly be of equal
length to avoid different quantities of air and heat being
distributed by each outlet.
125
45
ENGLISH
A
23

Publicidad

loading

Este manual también es adecuado para:

6096010