The outlets must be positioned at a height of no less than 2 m
from the floor to prevent the outgoing hot air from striking
persons;
- make two 185x185 mm openings on the wall or on the hood
where the ventilation openings are to be applied;
- position the galvanised support angles, previously bent, near
the opening in the inner part of the wall and secure them to the
wall with clamps;
- from the outside using a drill, drill three holes to fix the screws
as shown in the figure (drill the wall and the galvanised profiles
at the same time);
- use appropriate screws and from the outside secure the
galvanised support brackets to the wall;
- remove the clamps, previously used in the opening phase, to
secure the galvanised corner brackets supporting the wall;
- insert the structure for securing of the motor group in the holes;
- use the plastic band A supplied to secure the electric wiring of
the motor B and that of the temperature probe C to the motor
group support structure;
- with the screws and nuts supplied, secure the structure of the
motor group to the galvanised support angles;
Leave at least 300 mm of electrical cable above the locking
point, as shown in the figure, to facilitate subsequent removal
of the motor during maintenance.
WARNING: the electrical wiring must NOT be in
contact with hot parts.
THIS OPERATION MUST ALWAYS BE PERFORMED IN
THE ABSENCE OF ELECTRICAL POWER SUPPLY !!
C
B
ENGLISH
A
25