COMMANDS REGULATOR

IMPORTANT: with the heat generator on,
FIREBOX IS OPENED!
La NORDICA S.p.A. Is not responsible for any smoke exiting from the air vents !
The control regulator allows selection of the speed of the air in the environment and the desired temperature in a simple and intuitive way.
The regulator must be positioned far from the vents or from the main heat source; if positioned in the counter-hood it must be housed in a low
heat point. The simple installation is guaranteed by housing in classic recessed electrical boxes fitted in common buildings, or wall mounted
on the outside of the wall.
The controller activates the ventilation in MANUAL/AUTOMATIC mode selectable on the display in the controller by pressing/touching the
keys.
OPERATION of the regulator.
The device is switched on and off by pressing/touching the on/off button 1 .
In the off position, the light point of the ON key is lit. In this mode the system is in Stand-by mode, therefore always powered by the electric
voltage!
NOTE: when the air outlet temperature from the ventilation vents exceeds the pre-set safety threshold, the system enters SAfETY mode
activating the fans at the MAXIMUM speed to disperse excess heat as quickly as possible, until the system is safely restored. if this situation
occurs too often, contact the nearest Service enter.
By pressing the on/off button 1 , the status changes from the OFF state to the MANUAL or AUTOMATIC operating state and the respective
LED lights up. In the event of a blackout, the AUTOMATIC operating mode is restored!
Operation in MANUAL.
In MANUAL mode the fans always run at the speed set by the user, they are NOT subject to the temperature level set.
In the event that the temperature detected in the vents by the probe exceeds the pre-set safety threshold, the motors are automatically turned at
MAXIMUM speed to disperse excess heat as quickly as possible, until the system is safely restored!
Pressing key 2 switches from the fan SPEED setting mode to the desired TEMPERATURE setting mode in the room where the controller is
installed, and vice-versa.
The Speedis set when LED V is on (Blue colour) and is increased with key 3.
The speed value can be read from the blue LED in the scale to the side.
Key 3 increases the value to the maximum permitted then starts again from the minimum value.
AUTOMATIC operation.
The AUTOMATIC mode is useful for thermostating the room where the regulator is installed as well as ensuring optimal comfort thanks to the
automatic modulation of hot air introduced into the environment by the fans.
The user sets the desired temperature in the environment and the speed of the motors; maintenance of these settings is guaranteed by the
regulator that automatically controls switching on and off of the fans.
In the event that the temperature detected in the vents by the probe exceeds the pre-set safety threshold, the motors are automatically turned at
MAXIMUM speed to disperse excess heat as quickly as possible, until the system is safely restored!
Pressing key 2 switches from the fan SPEED setting mode to the desired TEMPERATURE setting mode in the room where the controller is
installed, and vice-versa.
The Speed is set when LED V is on (Blue colour) and is increased with key 3. The speed value can be read from the blue LED in the scale to the
side. Key 3 increases the value to the maximum permitted then starts again from the minimum value.
The Temperature is set when the LED C is on (orange colour) and increases with the key 3. The value of the temperature can be read from the
orange led in the scale to the side. Key 3 increases the value to the maximum permitted then starts again from the minimum value.
Led ON on = system in Stand-by under electric voltage.
Led AUT on = operation in AUTOMATIC mode; in this mode when
requested by the temperature probe, the LED corresponding
to the Thermostat symbol and/or to the fan symbol lights up.
MAN LED on = operation in MANUAL mode; in this mode the LED
corresponding to the Thermostat symbol is always Off and the
fan symbol is always ON.
Led °C on = SET temperature value active, with the + key set the
desired temperature; continuing to press the + key; having
exceeded the maximum value, the value starts again from the
minimum value.
Led V on = SET speed value active, with the + key set the desired
fan speed; continuing to press the + key, having exceeded the
maximum value, the value starts again from the minimum value.
28
turn the controller OFF EVERY TIME THE DOOR OF THE
1
functions selection key ON/AUT/MAN
2
functions selection key °C/V
3
Valuesincremental key
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

6096010