_CombiPower_IA_DE-IT.book Seite 95 Freitag, 21. Oktober 2011 8:10 20
CombiPower
Parameter
Explanation
Inv Off delay Determines the time after which
the device automatically
switches from the 230 V supply
to battery power.
(Disable = never)
Language
Sets the display language
New
Specifies the password. The
Password
password consists of 4 digits.
"I/P Parameter" menu (input parameters)
Parameter
Explanation
OVP Setting Overvoltage at which inverter
mode is deactivated
OVP
Voltage at which inverter mode
Recovery
is automatically reactivated after
being deactivated due to over-
voltage
UVP Setting Undervoltage at which inverter
mode is deactivated
UVP
Voltage at which inverter mode
Recovery
is automatically reactivated after
being deactivated due to under-
voltage
UV Alarm
Voltage at which an undervolt-
age alarm is triggered
EN
Configuring the device with the remote control
Value range
Disable, 1 – 10 min
English
Italian
Spanish
French
German
0000 – 9999
Value range
CombiPower 2012:
15 – 16 Vg
CombiPower 2024:
30 – 32 Vg
CombiPower 2012:
13.5 – 14.5 Vg
CombiPower 2024:
27 – 29 Vg
CombiPower 2012:
10.5 – 11.5 Vg
CombiPower 2024:
21 – 23 Vg
CombiPower 2012:
12.5 – 13.5 Vg
CombiPower 2024:
25 – 27 Vg
CombiPower 2012:
10.5 – 11.5 Vg
CombiPower 2024:
21 – 23 Vg
Default
Disable
English
0000
Default
16 Vg
32 Vg
14.5 Vg
29 Vg
10.5 Vg
21 Vg
12.5 Vg
25 Vg
10.5 Vg
21 Vg
95