CombiPower
No. in
fig. 4,
Symbol
page 4
11
12
13
EN
Explanation/function
Jumper for activating or deactivating an external
switch:
 Jumper open: external switch function
deactivated
 Jumper inserted (factory setting): external switch
function activated
4-pin plug
 PIN 1: ALM (alarm- function)
not currently activated
 PIN 2: CTL
Depending on the jumper (fig. 4 11, page 4) the
device can be forcibly switched on or off with a
positive signal.
Jumper open:
CTL input voltage 5 – 60 Vg = ON
CTL input voltage 0 Vg = OFF
Jumper closed:
CTL input voltage 5 – 60 Vg = OFF
CTL input voltage 0 Vg = ON
 PIN 3: –ENB, PIN 4: –VCC
The device can be switched on and off using
these pins. No external voltage is required for
this. –ENB is connected via a switch to –VCC
(–VCC may not be connected to the negative
terminal of the battery.)
See fig. 6, page 5:
Switch closed = device ON
Switch open = device OFF
Note: If the device is switched on using this
function, it can be be switched off with the main
switch only.
Socket for remote control connection cable