CombiPower
Parameter
Explanation
Ground
Specifies whether the earth relay
Relay
function is activated.
If the earth relay function is acti-
vated, the neutral conductor (N)
of the inverter output circuit is
automatically internally con-
nected to the safety earth
(PE/GND) when the device is
operating as an inverter. If alter-
nating current is supplied from
an external 230 V power source,
this connection is automatically
disconnected.
When the earth relay function is
deactivated, there is no connec-
tion between the neutral conduc-
tor (N) and safety earth
(PE/GND) when the device is
operating as an inverter.
Observe the regulations that
apply in your country for this
setting.
EN
Configuring the device with the remote control
Value range
Auto ON
Auto OFF
Default
Auto OFF
97