EHEIM Skimmarine300 Manual De Instrucciones página 18

Ocultar thumbs Ver también para Skimmarine300:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
English
Assembly
1. Install the pump again in reverse order.
2. Install the appliance again in reverse order.
7.
Clearing faults
Attention! Electrocution!
▶ Before clearing faults, remove the mains plug.
Faults
Pump does not start
No air bubbles, the pump is not
pumping
Residual air at the outlet
Dry foam, ineffective skimmer
performance
Moist foam, skimming too strong
High noise generation
For other faults, please contact EHEIM Service.
Possible cause
No mains voltage
Mains plug is not inserted
Impeller is blocked
can occur after the water is changed or
after cleaning
Skimmer is too low
Skimmer is too high
Air volume too low
Inlet and outlet openings dirty
Impeller is dirty
Skimmer is too low
Air volume too high
Impeller is dirty
Air volume too high
18
Remedy
▶ Check the mains
voltage
▶ Check the supply line
▶ Insert the mains plug in the mains
socket
▶ Clean the pump
▶ this ends automatically after approx.
1 day
▶ Position the skimmer higher
▶ Position the skimmer lower
▶ Increase the air intake with the air
adjustment controller
▶ Clean the inlet and outlet openings of
the housing and baffle plate
▶ Clean the pump
▶ Position the skimmer higher
▶ Reduce the air intake with the air
adjustment controller
▶ Clean the pump
▶ Reduce the air intake with the air
adjustment controller

Publicidad

Tabla de contenido
loading

Tabla de contenido