Model DSC30
BACKLIGHT OPERATION
1. Two backlight modes are available here: "No backlight" mode and "auto-backlight" mode. The "No backlight" will never show the
backlight under any condition. The "auto-backlight" mode will light up the backlight when any key is pressed or when the weight on
the scale is more than 5d. Five seconds later, the light will extinguish after the weight comes to "0".
2. Under the mode of weight measuring, you will enter into the other backlight mode by keeping pressing
mode, the scale will automatically keep the backlight mode set previously when you turn the scale on again.
CHARGE
When the under voltage indicator is glittering, it shows the insufficient power and you need to recharge it in time. Connect to the power
supply to make the AC indicator light up. This stands for it's charging now. The average charging time is 12 hours.
ELECTRIC QUANTITY INDICATION
1. When the under voltage glitters, it shows the insufficient power and need recharging in time.
2. If the display screen does not show or shows "Lo",this means The battery is in the self-protection state, and you should charge it in
time and then you can use it.
7. MENU SET
Press and hold
before turning the scale on. And you can enter the menu set. Yhe unit weight screen shows the tracing set informa-
tion and the weight screen shows the zero tracing value. Press
presetting key to confirm and enter the next set. After all the set is over, it will automatically back out from the menu set and back to
the weighing and counting mode.
Specific set as follows:
Serial number
Display
1
Zero:
Zero tracing
2
Zero:
Zero trangc
3
D-rng:
Dynamatic examination
Pass:
4
Warning internal and exter-
nal limit
Poind:
5
Average filter
5pnt:
6
Calibration mode
SPEED:
7
Sample speed
8
Auto-averaging
Bps
9
Baud rate:
Counting scale
Set value
0d
1d
2d
3d
0d
1d
2d
3d
0d
1d
2d
3d
0
1
4
8
16
0
1
0
1
0
1
300
600
1200
2400
4800
9600
19200
to choose zero tracing value: 0d, 1d, 2d, 3d, and press the warning
Set introduction
0 stands fro no tracing.
1 stands for tracing 1d
The bigger tracing vlue, the quicker back to zero.
The bigger the set value, the quicker back to zero.
The bigger dynamic value is, the more stable is. But the resolution is
worse and it's suitable to be used in a worse enviroment.
0 stands for the warning internal limit presetting
1 stands for the warning external limit presetting
The bigger the filter point is, the more stable the scale is. But the
reaction speed is lower.
Single point calibration mode
Multipoints calibration mode
Factory set
Fast sampling
Allow auto-averaging
Forbid auto-averaging
Choose the baud rate according to the printer (only the scale with
printing connector can funtion).
User's Guide
key. After setting the