6 INSTALLATION
6.1
ASSEMBLY DIAGRAM
Fig. 6.1 illustrates an example assembly diagram.
For proper installation, the smoke ducting between the
material suitable for high temperatures.
the combustible materials which deposit on the walls of
On all Ecomonoblocco units, on the outer sides of
installed with a thickness of 4 cm and a density of 40
3
on an aluminium foil base, to thermally insulate
Installation requirements include installation of a
heat recovery grille as close as possible to the ceiling
(around 20 cm).
Incorrect installation may compromise safety of the
unit.
materials must be 80 cm.
All combustible materials must be placed at least 170
cm away from the area where heat radiates from the
glass door. (Fig. 6.2).
170 cm
cod. 004771651 MBL - 10/2015 - Palazzetti - PN - Italy
INSTALLATION
A
B
A) SEAL
B) EXTERNAL AIR INTAKE (UNDER FIRE BED)
C) HEAT RECOVERY GRILLE
D) COUNTER-HOOD AND FIREPROOF LOAD BEARING
STRUCTURE
E) CLADDING IN CERAMIC FIBRE OR ROCK WOOL WITH
EXTERNAL ALUMINIUM FOIL
F) INSPECTION PANEL
G) SHIELD THE WOOD PARTS WITH FIREPROOF MATERIAL
H) MINIMUM DISTANCE 5 mm BETWEEN CLADDING AND
FIREPLACE STOVE
- 6.2 -
C
D
E
F
G
H
- 6.1 -
33