6.5
CONNECTION TO FLUE PIPE
with EN 13384-1.
It is advisable to make the connection for smoke outlet
metallic pipes of a suitable thickness, taking care not to
exceed and inclination of 45° (see Fig.
B
When the connection has been made, it is
to insulate the metallic pipes of the smoke outlet with rock
wool which may be externally covered with aluminium
foil.
All components making up the chimney system must
conditions and CE marked.
6.6
AIR INTAKE CONNECTION
It is necessary to provide an external air intake to
The dimensions of the hole must comply with the values
set forth in the table of technical data shown in the
"Product booklet".
According to local standards in force, air intake could be
Is forbidden the intake of air for combustion from
The combustion air intake should be protected by
an anti-insect grille and placed where it can not be
accidentally obstructed, and made in such a way that the
useful cross-section allows the right amount of oxygen
one or more extraction fans (exhaust hoods and the like),
there may be problems with combustion due to lack of
combustion air.
For rooms greater than 25 m
room air recirculation grille (A) alongside the cladding
or use the wood compartment if there is one (G) (Fig.
6.9a).
6.6.1
Combustion air intake
Some models of Ecomonoblocco may be fitted (as
in the bottom compartment (P, Fig. 6.9b), for combustion
air connection to the outside air intake (C) via suitable
ductwork. For connections exceeding 1 m in length,
the diameter of the combustion air intake duct must be
increased.
On Ecomonoblocco models with smaller support feet, this
solution is only available when applying the extension leg
kit.
36
INSTALLATION
A - curve,
C - short section)
.
advisable
.
.
2
it is advisable to provide a
max 45°
A
H=2D
D
C
A
C
A
cod. 004771651 MBL - 10/2015 - Palazzetti - PN - Italy
B
C
- 6.8 -
G
- 6.9a -
P
G
- 6.9b -