HOT AIR DELIVERY CONNECTION
6.7.1
Connection in counter-hood for single-room
heating
Install the flexible pipes (diameter 140 mm) for hot
air distribution to the outlet nozzles, above the hood,
securing them with the special clamps. Soundproof the
pipes by cladding them with the insulating material (rock
C-insulation, D-outlets).
6.7.2
Connection to ducting for multi-room heating
To heat more than one room it is possible to realize
metallic conduits for air distributon in accordance with
the following scheme
conduit
smooth metallic pipe or ducting - length up to 12 m on
second conduit can be used to carry hot air to the other
rooms of the home. As an alternative, connect the hot
distribution ducts. The conduits for air distribution must
have an internal cross-section of 25x20 cm, made of
smooth galvanized sheet metal and insulated with 30 mm
adjacent rooms, it is indispensable to allow for air
circulation so as to have the same temperature in the
various rooms. Therefore, place ventilation grilles on the
doors or leave the doors ajar.
AIR DUCTING DIAGRAM
BM = Ceiling delivery outlet complete with calibration shutte
Ventilation grille in lower part of door
GT=
A+B = Room air intake grilles with 14 cm holes, connected
C = External air intake opening located under the grate for
D = Hot air distribution with galvanized steel ducting located in
the ceiling, net internal cross-section 25x20 cm, for a length of
with a thickness of 3 cm, possible coveringin plasterboard.
cod. 004771651 MBL - 10/2015 - Palazzetti - PN - Italy
INSTALLATION
A-clamps, B- distribution pipe,
(Fig. 6.12)
B
A
A
15x15
C
A
D
GT
GT
BM
C
D
- 6.10 -
25x20
B
- 6.11 -
B
BM
BM
BM
- 6.12 -
37