Fault indicator
DC IMBALANCE
DC ISOLATION
DC VOLTAGE
LEAKAGE CURRENT
AC CONNECTION PE
AC CONNECTION N
LINE FREQUENCY
MAINS VOLTAGE
Voltwerk VS 3, 4, 5
Possible cause
| Imbalance in internal
voltage
| Electronics fault
| Earth leakage of the
solar generator
| Atmospheric charge
| Solar power system
field designed or con-
nected incorrectly
| Leakage current is too
high
a
| Faulty grid connection
| Faulty PE connection
| Wrong grid type
| Earth resistance is too
high
| Faulty grid connection
| Mains plug installed
incorrectly, (L and N
interchanged)
| Wrong grid type
| Earth resistance is too
high
| Line frequency is
outside tolerance
| Mains plug installed
incorrectly
| AC overvoltage
| Mains plug installed in-
correctly
| Grid impedance is too
b
high
Operating manual
8 Help in the case of faults
Possible fault rectification
| Check solar power system
field for earth leakage
| Check the idling voltage of the
solar power system field
| If the fault continues, contact
the manufacturer's service
centre (contact information on
the back of the manual).
| Check solar power system
field for earth leakage
| Wait for improvement in the
weather
| Check the voltage of the solar
power system field
| Check solar power system for
earth leakage
| Check installation and con-
nector pin assignment (see
chapter 5.2, page 30)
| Check grid type (see
chapter 3.7, page 19)
| Check installation and con-
nector pin assignment (see
chapter 5.2, page 30)
| Check grid type (see
chapter 3.7, page 19)
| Check installation and con-
nector pin assignment (see
chapter 5.2, page 30)
| Check power cable
| Check line frequency
| Check installation and con-
nector pin assignment (see
chapter 5.2, page 30)
| Check AC fuse
| Controlling mains voltage