4.3
OVERHEAD DOORS CONFIGURATION
ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams on page 52.
1-2
+24 V
3-4
22 V ~ transformer power supply input
5-6
24 V
battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity indications).
7-8
Operator 1 output
9
Connection of motors metallic parts
10-11
Operator 2 output (if present)
12-13
24 V
max 15 W output for open gate fix/flashing warning light (if P052=0/1) or courtesy light (if P052>1)
14-15
Electric-lock output max 1 art. 110 (if P062=0) or 24V
16-17
24 V
Flashing light output max 15W art. Lumy/24A/S
18 - N.O.
18-19
Input 6. Unused.
19 - Com
20 - N.O.
20-21
Input 5. Unused.
21 - Com
22 - N.C.
Input 4 STOP . In case of intervention, it stops the movement of both motors during any
22-23
operation. If unused, short circuit.
23 - Com
24 - N.C.
Input 3 SAFETY. If activated, it causes the inversion. See P055 and P056 on the parame-
24-25
ters table. If unused, short circuit.
25 - Com
Input 2 PHOTO 1. When enabled (see parameter P050 in the table), activation of PHO-
26 - N.C.
26-27
TO 1 provokes: an inversion of direction (during closing), the arrest of the movement
(during opening), prevent the start (gate closed). If unused, short circuit.
27 - Com
28 - N.O.
Input 1 START. In case of intervention it provokes: the operator opening or closing. It may
28-29
operate as "inversion" mode (P49=0) or "step by step" mode (P49=1).
29 - Com
30
Aerial signal input
31
Ground aerial input
32-33
DEA_NET net input (unused at the moment)
CON 1
230 V ~ ±10% (50/60 Hz) power supply input
Encoder selection Jumper:
J5
J9
•A position = operators with encoder (remind to set P029=0)
B
A
B
A
•B position = operators without encoder (remind to set P029=1)
Table 1 "terminal board connections"
power supply output for auxiliary devices 200mA
output max 5W configurable (if P062≠0)
51