5
Selection 1 or 2 operators functioning
1. Scroll down the parameters with
sualise P030;
2. Access the parameter by pressing the
3. Acting on
and
- d001=for a single motor operating;
- d002=for 2 motors operating;
4. Confirm your choice by pressing the
again to P030).
6
Selection of direction of motion
1. Scroll down the parameters with
until you visualise P063;
2. Access the parameter by pressing the
3. Acting on
and
- d000=motor in standard position (on the right of
the gap);
- d001=motor in inverted position (on the left of
the gap);
4. Confirm your choice by pressing the
returns again to P063).
7
Motor stroke learning
1. Scroll down the parameters with
2. Access the parameter by pressing the
3. When "
" flashes, continue pressing the
4. Release the
key when "
5. Wait for the boom (or booms if two opposite barriers) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to "Start" button
(or pressing the "OK" on the control panel) simulating the stroke.
6. Once the procedure is ended, the display will show "----".
8
Transmitters learning
8.1 Transmitters coding selection
1. Scroll down the parameters with
P027;
2. Confirm by pressing on the
3. Select the type of transmitter by scrolling
- d000=fix rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
4. Confirm by pressing on the
Warning: If you need to vary the type of encoding, and only if other
remotes with different encoding are memorized, you need to erase
memory (P004) AFTER you have set the new encoding.
60
and
keys until you vi-
key;
keys, set:
key (display returns
and
keys
key;
keys, set:
key (display
and
keys until you visualise P003;
key;
key;
" stops flashing; the learning procedure starts;
and
keys until you visualise
key;
and
key (display shows again P027).
keys: