Fasten the red cable (1) to the positive (+)
terminal of the battery with the screw (2),
washer (3) and nut (4).
Tighten the connection to a torque of
4 - 5 Nm using two A/F 8 spanners. Fit
cap (5) to completely cover the
connection.
Fasten the black cable (1) to the
negative (–) terminal of the battery with the
screw (2), washer (3) and nut (4).
Tighten the connection to a torque of
4 - 5 Nm using two A/F 8 spanners.
0478 192 9809 A - EN
Lift the battery (1) and tilt inwards slightly.
Carefully insert the battery, making sure
that the two connection cables are
properly stowed in the battery
compartment.
● Close the battery compartment.
(
15.18)

15.20 Fuses

Fire hazard!
Never bypass the fuses with wire or
foil.
Never use a fuse with a value that
differs from the specified rating
(amperes).
If a new fuse blows within a short
time, an electrical fault (e.g. short
circuit) is the probable cause.
We recommend that you consult a
specialist dealer. STIHL
recommends STIHL specialist
dealers.
Checking the plug-in fuses:
The plug-in fuses are located in the battery
compartment.
● Stop the engine. (
13.3)
● Engage the parking brake. (
● Remove the ignition key and keep it in a
safe place.
● Open the battery compartment.
(
15.18)
Remove the plug-in fuses (1,2). Visually
check whether the wire (3) in the plastic is
damaged (burnt through).
Replace damaged fuses.
Charging device (1): 15 A
Electrics (2): 10 A
● Close the battery
compartment. (
15.18)
Checking the main fuse:
The main fuse (150 amps) is located
behind the battery.
● Remove the battery. (
15.19)
8.14)
55