PREVENTIVE MAINTENANCE
5
2
Máx.
3
Mín.
4
1.
Air/oil separator element
2.
Oil fill in plug
3.
Oil level sight
4.
Oil drain valve
5.
Screws cover tank
6.
Safety valve
FIGURE 17
2.1 RECOMMENDED OIL
There is a sticker on the air/oil tank indicating the type of oil used for the factory fill of your air compressor.
This compressor can also be operated with synthetic and non-toxic synthetic oils which will change the
maintenance (oil replacement) interval is to 6,000 hours. The first oil filter change must occur at 300 hours
and the subsequent ones at every 2,000 hours*.
Changing oil types is not highly recommended, as chemical incompatibilities can cause damage to the
machine.
* Consult the factory or SCHULZ Authorized - Technical/Distributorfor oil recommendation and additional
orientations.
IMPORTANT
The first filter change must be carried out with 300 operating hours with subsequent changes every 1,000
hours (on the Electronic units, this interval is indicated on the display SRP 3040E and model SRP 3040 is
indicated on the panel "check control".
AMBIENT TEMPERATURE
0
OF -10 C TO 20 C
0
OF 14 F TO 68
DTE 24
RANDO HD 32
TELLUS 32
COMPTELLA 32
TABLE 3 - RECOMMENDED MINERAL OIL FOR SCREW AIR COMPRESSOR
2
1
6
FIGURE 19 - OIL FILTER
0
0
0
OF 20 C TO 40 C
0
0
F
OF 68 F TO 104
DTE 25
RANDO HD 46
TELLUS 46
COMPTELLA 46
1
FIGURE 18
FACTORY
0
F
MOBIL
TEXACO
SHELL
1
1. Oil drain valve
FIGURE 20
FIGURE 21
53

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Srp 3040

Tabla de contenido