Installation Instructions; En Instructions For Use / Assembly Instructions - Hansgrohe Ecostat 1001 SL 13261 Serie Instrucciones De Montaje

Ocultar thumbs Ver también para Ecostat 1001 SL 13261 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the
valid norms!
Thermostatic mixer in conjunction with
combination boilers
If fitting a hand shower remove the water limiter from
the shower.
If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Thermostatic mixer Shower: When using the Ecostat
with combination boilers, the Ecostop safety set
95042000 has to be removed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
anti-pollution function
6 6
English
Symbol description
max. 1 MPa
0,1 – 0,5MPa
1,6MPa
max. 80°C
65°C
Do not use silicone containing acetic acid!
Safety Function (see page 62)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
Adjustment (see page 63)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
ECOSTOP (see page 64)
Maintenance (see page 65)
To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN
EN 1717 in accordance with national
or regional regulations (at least once a
year).
Operation (see page 66)
Dimensions (see page 68)

Hide quick links:

Publicidad

Tabla de contenido
loading