Installer - System Programming Using The Keypad - LiftMaster EL1SS Manual De Instalación Y Configuración

Ocultar thumbs Ver también para EL1SS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INTRODUCTION

INSTALLER - SYSTEM PROGRAMMING USING THE KEYPAD

The following pages are a reference to the programming options for setting up the EL1SS using the keypad . The programming steps
below are used by the installer for initial set up (occasionally used by a resident) . The programming options on pages 15-17 can be used
by the resident or installer . The unit's master code is used at the beginning of all owner/administrator level commands .
TIMING FOR PROGRAMMING ENTRIES
Programming that starts with the master code entry require that the string of digits are entered without a pause between master code
and programming step (The master code has dual functionality; it also acts as an entry code when it is entered by itself) .
PROGRAM
DESCRIPTION OF FUNCTION OR SETTING
NUMBER
03
ENABLE INTERCOM (NO TELCO) MODE
Factory Setting: Disabled
Intercom Mode allows for communication between the unit
and a resident's phone without a telephone line (the system
generates its own signal) .
04
ENABLE TELCO (NO INTERCOM) MODE
Factory Setting: Enabled
Telco Mode uses the residence's telephone line for the unit's
communications to the resident's phone(s) and/or to dial out
to the forwarded telephone number .
06
SPEAKER VOLUME
Factory Setting: Level 2
Allows the visitor to hear the resident at the unit,
1 = Low, 2 = Medium, 3 = High .
For proper adjustment under typical conditions (inside a
parked running car) . Ask the resident to speak in a normal
tone . Adjust up or down as necessary .
07
MICROPHONE SENSITIVITY
Factory Setting: Level 2
Allows the resident to hear the visitor at the unit,
1 = Low, 2 = Medium, 3 = High .
For proper adjustment under typical conditions (inside a
INTRODUCTION
parked running car using a normal voice tone), ask the
resident if the audio is appropriate . Adjust up or down as
necessary .
09
CHANGE THE MASTER CODE
Write down the Master Code and store in a secure location.
021
ENABLE PARALLEL RELAY OUTPUT
Factory Setting: Disabled
023
ENABLE INDEPENDENT RELAY OUTPUT CONTROL
Factory Setting: Enabled
024
ADJUST RELAY OUTPUT TIME (RELAY 1)
Factory Setting: 0 .5 seconds
The amount of time (in seconds) the relay remains active
025
ADJUST RELAY OUTPUT TIME (RELAY 2)
Factory Setting: 0 .5 seconds
The amount of time (in seconds) the relay remains active
*Example: 0000 = 0 .5 Seconds (minimum) 0010 = 10 Seconds 8000 = 8000 Seconds (2 hours 13 minutes, maximum)
INSTALLATION
INSTALLATION
TEST
PROGRAMMING STEPS
Master Code
(4 digits) +
Master Code
(4 digits) +
Master Code
(4 digits) +
(1
= Low,
2
= Medium,
Master Code
(4 digits) +
(1
= Low,
2
= Medium,
TEST
Master Code
(4 digits) +
Master Code
(4 digits) +
Master Code
(4 digits) +
Master Code
(4 digits) +
seconds*) NOTE: Relay output time is ALWAYS 4 digits.
Master Code
(4 digits) +
seconds*) NOTE: Relay output time is ALWAYS 4 digits.
14
SET UP
03
04
06
+ Volume Level
3
= High)
07
+ Volume Level
3
= High)
SET UP
09
+
# # #
+
New Master Code
021
023
024
+ Relay Output Time
(0000-8000
025
+ Relay Output Time
(0000-8000
(4 digits)

Publicidad

Tabla de contenido
loading

Tabla de contenido