Technical Data - Migatronic ZETA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
Power source:
Mains voltage ±15% (50Hz-60Hz)
Fuse
Mains current, effective
Power, (100%)
Power, max
Open circuit power
Efficiency
Permitted load:
100% duty cycle (40°C ambient temp)
60% duty cycle (40°C ambient temp)
40% duty cycle (40°C ambient temp)
35% duty cycle (40°C ambient temp)
100% duty cycle (20°C ambient temp)
60% duty cycle (20°C ambient temp)
Open circuit voltage
Current range
1
Application class
2
Protection class (IEC 529)
Standards
Dimensions (hxwxl)
Weight
Cut quality
Cut max.
Autotransformer:
Mains voltage ±15% (50Hz-60Hz)
Mains current, effective
Mains current, max.
2
Protection class
Dispose of the product according to local standards
and regulations. More information can be found
under Policies at www.migatronic.com
S
1
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock
2
Equipment marked IP23/IP23S is designed for indoor and outdoor applications

TECHNICAL DATA

ZETA 60
ZETA 100
3x400 V
3 x 400 V
10 A
20 A
6.8 A
19.1 A
4.7 kVA
13.2 kVA
7.4 kVA
29.9 kVA
< 35 W
< 35 W
0.9
0.8
Cutting
40 A / 96 V
75 A / 110 V
50 A / 100 V
85 A / 114 V
60 A / 104 V
100 A / 120 V
-
-
45 A / 98 V
-
55 A / 102 V
-
241 V
248 V
20-60 A
20-100 A
S
S
IP 23
IP 23
EN/IEC60974-1
EN/IEC60974-10 (Class A)
360x220x570 mm
405x345x675 mm
27 kg
36 kg (6 m)/39 kg (15 m)
12 mm
<25 mm
18 mm
<35 mm
MFA 403 (ZETA 60)
MFA 401 (ZETA 100)
3x230 V
3x230-500 V
3x400 V
3x440 V
3x500 V
31.0 A (230V)
35.8 A (230 V)
17.0 A (400V)
20.6 A (400 V)
16.2 A (440V)
18.7 A (440 V)
14.3 A (500V)
16.5 A (500 V)
40.0 A (230V)
47.4 A (230 V)
22.0 A (400V)
27.2 A (400 V)
20.9 A (440V)
24.8 A (440 V)
18.4 A (500V)
21.8 A (500 V)
IP23S
IP 23
12
Gouging
75 A / 130 V
85 A / 134 V
-
100 A / 130 V
-
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zeta 60Zeta 100

Tabla de contenido