The filter unit should undergo a visual inspection quarterly.
Proceed as follows:
− A qualified electrician should check all cables for damage.
− Check the pneumatic connections and hoses for signs of damage or leaks.
− Check the filter unit for visible damage.
− Check the compressed air regulator setting. The pressure regulator is in the fan
component behind the service plate.
Proceed as follows:
• Switch off the filter system and ull out the mains plug.
• Remove the rear service cover of the ventilator component.
• The pressure for the compressed air container must be reset at the pressure
regulator (item1) to 5 bar if need be.
Part no.: 150 2627 (CAT 2.0)
All rights over changes without prior notice and errors reserved.
KEMPER CleanAirTower 2.0 Operating instructions - EN
Figure 13, setting the pressure regulator
- 72 -
Rev.: 00
Issue: 02/2017