Descargar Imprimir esta página

Sterling Power ProCharge ULTRA Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

(Optional) Battery Chemistry Module
Multi battery chemistry and voltages output options
Battery Charger Chemistry Modification Module
Another great idea from Sterling. Patent Pending: GB1204145.5
What was the issue which led to the invention of this device?
A lot of new installations on modern boats require different chemistry and
even different voltage levels. For instance, you may have a 12V charger
but a 24V bow thruster or vice versa. You may also have an open lead acid
battery banks and a Lithium. This causes impossible challenges for a
standard battery charger or you may simply have one battery bank a long
way from another bank requiring very expensive cable runs to prevent
voltage drop, ( no longer a problem with the BCM ).
The solution
The new Sterling Battery Chemistry module has a unique approach to solving
this problem. We effectively place in a box a voltage booster and the output
stage from a digital charger. This means that the new device can be added to
any of the output terminals of our Pro Charge Ultra
on to most other competitor companies multiple output charger).
allow the main 3 (or more) output charger to be set at the lower chemistry
voltage for the likes of Gel (14.1V absorption), then, by adding the new Sterling
Multi chemistry module to one of the outputs (must be connected to an output of
a current limiting charger and cannot be connected direct to a battery. One can
adjust that output to a totally different charging chemistry profile. The output
voltage and charging curves are independent of the charger's input voltage.
This enables a totally different chemistry to be selected. This gives all the
advantages of the multi chemistry charger without the huge extra cost, and can
be simply retrospectively fitted to any multi output battery charger (within the
limitations of the product).
Example - A 12V starter battery bank (sealed lead acid).
A Lithium main battery bank and a 24V open lead acid Bow Thruster.
www.sterling-power.com
Earth /chassis
boats bonding
AUTO CONSERVATION MODES
RoHS
compliant
Main Charger
set to 14.4V
sealed lead acid
(or can be used as an add
Pro
Charge U
LTRA
Sterling Power
GLOBAL AC Input & Active Power Factor Correction
Progressive DIGITAL software control Charger / Powerpack
CEC
www.sterling-power-usa.com
approved
AC Power
Auto Temp Control
Volts
Amps
Active PFC
Safety Certified by: TUV
0%
100%
Built and tested to
Multi Speed Fan
1 2 3
Charger Output
UL 1236 SB
Stand-by
Battery Health Program
CSA C22.2-107.2
Absorption
Float
CHARGER MODE
Fast Charge
System self test
De-sulphation
CHARGE INFORMATION
Battery Type
OK
Open lead acid
DC Output Fault
Fault
Sealed lead acid
DC Low Voltage
DC High Voltage Trip
A.G.M
High Charger temp trip
GEL
SETUP
Lithium (LiFePO
)*
Check Fan
4
ENTER
Calcium /
Custom
*Lithium must be used in conjunction
with a lithium balancing system.
High Voltage AC
WARNING
Low Voltage DC
Battery Chemistry
module 1
set to LiFePO
12V
_
+
12V Sealed engine
starter Battery bank
Advantages of this product
1) Easy to install.
2) Fits our products and most of our competitors multiple output chargers.
or converts a single output charger into a multiple output charger.
3) 12-12V, 12-24V, 24-24V and 24-12V models.
4) 8 selectable independent latest battery chemistries to chose from and a de-
sulphation cycle, also LiFePO
5) Battery temperature compensation and high battery temperature trip.
6) Remote battery sense compensate for cable voltage drop.
7) 6 LEDs projecting over 20 individual charge and warning information
events.
8) Fail safe, reverts to basic charge function - about 1V less in event of a
failure. Product can be replaced / repaired at convenience.
9) High battery temperature "daisy chain" trip ( optional ). This allows every
battery to be monitored and the unit can be switched off in the event of battery
overheating - causing high battery temperature related problems.
10) Ignition fed generator to link in with sterling Pro Split R alternator splitter,
this allows the output to be further split.
11) Remote control available as an optional extra.
This will
Which model suits my needs.
equal to or less than the rating of the product. I.e. a 12V 60A module can be
used on any charger up to 12V 60A .
Do you want to simply add a chemistry option.
but maintain the same base voltage i.e. 12V or 24V. In which case the
BCM1260 will allow a totally separate battery type in the 12V charger.
Do you want a different base voltage and battery type.
charger but you want to also charge a 24V battery bank. In this case, go for the
BCM 12V-24V option this allows for the different voltage and chemistry
Long cable runs.
You may have a very long cable run from the main charger
to an important auxiliary battery. Simply add one off these units at the end off
the run to boost up the voltage to the required battery type, thus reducing
cable thickness requirement and hence cost .
(remote control not required for operation)
Absorption
Condi
H Charge
Sterling Power Products
V
12.2
In / Unit
Bat - Chem - Unit
Audible alarm on/off
hold >5 sec
Volts
Alarm
Unit on/off
Select
hold > 5 sec
Fault
Battery Chemistry
module 2
set to 24V AGM
4
12V
_
_
+
12V LiFePO
Lithium
24V Bow thruster
4
Main Battery bank
Battery bank AGM
cycle .
4
Ensure that your current charger's output is
I.e. a different battery type
Battery Chemistry module
and optional remote control
Float
Out / Rem
Batt.
Temp
Menu
Setup
24V
+
I.e. you have 12V

Publicidad

loading