Pro Charge Ultra Remote Control
B
to install
Slide parts A to expose screw holes.
A
For flush mount, remove part B.
For surface mount, keep part B.
After installation, replace parts A.
Operation:
Power, Start Up and Language Selection:
a.
If breaker is turned on and charger has AC power the remote is lit with the
backlight on.
"Language Select: English" (factory default) will display and flash for 5
b.
second. The operator can select the language during these 5 seconds by
pressing the UP or DOWN keys to toggle through all of the available
languages (English, German, Spanish, Italian, French) and then press
SETUP/ENTER key to confirm.
If no selection is made within these 5 seconds, the default language shall be
selected.
(If you wish to change the language at a later date, refer to 'language selection'
section below).
c.
Charger mode will displayed (Charge, Conditioning, Ready) along with voltage
and amperage until another mode is selected.
Button Operation – with AC power applied to the charger
a.
(Backlight) Button Operation:
1.
Press On-Off for about 1 sec the backlight will turn OFF. Warning
If you hold for more than 4 sec the complete charger will switch off
2.
Press On-Off for about 1 sec the backlight will turn back ON.
b.
(Alarm) Button Operation:
1.
Press Alarm to turn audible alarm OFF.
2.
Press Alarm to turn audible alarm ON.
c.
(Setup / Enter) Button Operation
***(If not selection is made within 10 seconds charger defaults to prior setting).
1.
Press the Setup/ Enter button once
2.
This will now allow you to toggle through all available functions using the
↑or ↓
a.
Scrolling – (Must push Setup / Enter to confirm) = will
display all of the below one at a time for 4 seconds
automatically scrolling through the menu functions.
b.
Charger Name
c.
Charger Status (Same display shows both)
d.
Battery Type Selection (Flooded Preset 1)
e.
Time to Absorption
f.
Run time during this session
g.
Current Set Power Level should be 100% unless in Power
Level mode. If a different Power Level is selected the
charger will read 100, 75, 50, 25%.
h.
Battery Temperature
i.
Charger Temperature
j.
Transformer Temperature
k.
Faults
l.
Company Information
m.
Total Run Time
n.
Software Revision
3.
Once the remote is displaying the desired function press Setup / Enter
button once to show this functions detail. To change selection repeat
i. Mode displaying (Charging, Conditioning or
Ready)
ii. Output Voltage
iii. Output Current
i. Over Voltage
ii. Under voltage
iii. Battery Over Temperature
and scroll through to the required information.
Button Functions:
d.
Both the ↑or ↓ are used for toggling up and down through the menu options after the Setup/
Enter button has been pressed
Additional Charger Modes
FORCE TO READY/FLOAT Maintenance = "Hold" 10 Seconds
The force to float mode is not necessary for standard operation.
1.
Hold the ↓ button down for 10 seconds.
2.
The display will stop scrolling and a "Beep" sound to confirm
entered into this mode after button released.
3
The charger will go to float mode and will remain in float until
battery voltage drops to a level where Charge is require or until
power is recycled.
If you do use this function to get out off it you must switch the charger off
at the main AC power source to reset this.
POWER LEVEL ADJUSTMENT = "Hold" 15 Seconds
I. Hold "↑"both "↓" down together for 15 seconds.
II. The display will stop scrolling and a "Beep" sound to confirm entered into this
mode after buttons released.
III.. Press "↓"to adjust the Amperage display from 100, 75, 50, 25% output.
IV. Once Power Level is desired confirm the selection by pushing "Setup/ Enter".
V. If no actions are taken in 15 seconds the unit reverts to 100% power.
VI. Remote will display Power level at % that is selected (100, 75, 50, 25 for one
second on, then one second off, then on displaying Voltage and Amperage at
that selected power level).
VII. Once a power reduction is selected it remains permanent until re-programmed
again.
VIII. To re-adjust the power level follow steps 1-5 making sure to confirm 100% to
resume normal operation.
IX. When in power level mode selection display (Power Level 50% and output
voltage/ current.
Setup
SYSTEM SELF TEST MODE = "Hold" 8 Seconds
Enter
I. To test the chargers system hold all three (Setup/ Enter, ↑, ↓) buttons down for
5 seconds,
II. The display will stop scrolling and a "Beep" sound to confirm entered into this
mode after buttons released.
III. The charger will "Self Test" and if normal display "System OK" if not a failure or
failures will be displayed. If more then one failure exists you can push ↑or ↓ to
view the failures.
IV. Press Setup/Enter to go to other functions when complete.
Setup
Alarm
Enter
I. To restore the Factory Defaults "hold" Alarm, Setup/Enter, and ↑, ↓down for 3
seconds.
II. The charger will then restart with the factory defaults.
Output ON/OFF function (For Sterling version only)
a.
Press and hold Power button for 4 second to turn the charger
output OFF
b.
When charger is OFF, press Power button to turn the charger
output ON
How to change language once a language has been selected or defaulted to English
1.
Press and hold SETUP/ENTER key for 3 seconds, the display will go to
language selection mode.
2.
Remote will display the current language and flashing for 5 seconds.
3.
Select language within these 5 seconds by pressing UP or DOWN key to toggle
through all available language
4.
Press SETUP/ENTER key to confirm
5.
If no selection is made within these 5 seconds, the language will keep as
default or previous setting unchanged.
6.
Remote will go back to normal operation
7.
The display sequence of language is English, German, Spanish, Italian, French
IMPORTANT SAFETY INSTRUCTIONS
I
SAVE THESE INSTRUCTIONS - this manual contains important safety instructions for the
Charge Ultra
1) Do not expose this unit to rain or snow.
2) Use of attachments not recommended or sold by Sterling Power will void warranty and may
result in the risk of fire.
SHOCK OR PERSONAL INJURY.
3) Do not operate the unit if it has been dropped or visibly damaged in any way
4) Do not disassemble the unit. If service or repair is required please contact Sterling at:
FACTORY RESET = "Hold" 3 Seconds