Section 6
Multiple units in parallel mode
The power supply 1672 can be connected two or more units in parallel to
obtain a higher current output (Max. 24A only).
1.
2.
The output voltage of the system will be the same for all the units. The output current
of the system will be the sum of each unit.
This is the standard 5V/ 3A power output provided for supplying the power to TTL
logic circuits. When the load exceeds 3A. The red OVER LOAD LED (4) will light up.
The output voltage will lower and the power supply will be under C.C. Mode.
Set all the 1672 which will be connected in parallel operation under
parallel tracking mode as described in parallel tracking mode and ad-
just all units to the same output voltage.
Make the parallel connection of Positive and Negative terminals of
Master and Slave outputs of all units.
FIXED 5V/3A OUTPUT
8