3062-3M-Bklt Jupiter AFU/WE-rv
18/3/08
USER INSTRUCTIONS
Please read these instructions in conjunction with the 3M Jupiter™ Reference leaflet where you will find
information on:
• Approved combinations of Headtops
• Spare parts
• Accessories
UNPACKING
Your Jupiter™ Air Filter Unit (AFU) should contain:
a) Jupiter™ unit
085-00-10P
b) Belt
022-25-03P/BLT-12
c) Air flow indicator & Calibration Tube
021-14-12P
d) User instructions
QX-3800-1031-1
e) Reference leaflet
QX-3800-1032-9
FOREWORD
Failure to follow all instructions on the use of this product and/or failure to wear the respirator system during all times of
exposure may adversely affect the wearer's health, may lead to severe illness or permanent disability and may render any
warranty null and void.
If you have any doubts about the suitability of the product to your job situation, it is recommended that you consult an
occupational hygienist, or call 3M OH&ES Technical Affairs at your local 3M office.
See back of this booklet for addresses and telephone numbers.
SYSTEM DESCRIPTION
Jupiter™ is a waist mounted air filter unit which when used in conjunction with one of the approved headtops (see reference leaflet)
forms a power assisted filtering device.
The Jupiter™ system offers a choice of 4hr, 8hr or Intrinsically safe (I.S.) battery packs, a range of filter options and
incorporates an electronic control unit which provides an audible and visual warning of low battery and/or low airflow into
the headtop.
APPROVALS
This product, when used as part of a 3M Approved System has been shown to meet the Basic Safety Requirements under Article 10
and 11B of the European Directive 89/686/EEC and is thus CE marked.
The product was examined at the design stage by: British Standards Institution, Product Services, Maylands Avenue, Hemel
Hempstead, Hertfordshire, HP2 4SQ, England (Notified Body number 0086).
This product has been certified as complying with European EMC Directive 89/336/EEC.
This product (when fitted with the Intrinsically safe I.S. battery pack 007-00-62 and I.S. pouch 085-11-00) has been certified as
complying with the relevant standards for intrinsic safety described in the Marking section by: SIRA Certification Service, UK
(Notified Body number 0518).
LIMITATIONS TO USE
Use this respirator system strictly in accordance with all instructions:
• contained in this booklet,
• accompanying other components of the system (e.g. 3M Jupiter™ Reference leaflet, Headtop and Filter User Instructions).
Do not use in concentrations of contaminant above those given in the Headtop User Instructions.
Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations of contaminants are
unknown or immediately dangerous to life or health (IDLH), or in atmospheres containing less than 19,5% oxygen (3M definition.
Individual countries may apply their own limits on oxygen deficiency. Please seek advice if in doubt).
Only use with the headtops and spares / accessories listed in the Reference leaflet and within the usage conditions given in the
Technical Specification.
Only for use by trained, competent personnel.
Leave the contaminated area immediately if:
a) Any part of the system becomes damaged.
b) Airflow into the headtop decreases or stops.
c) Breathing becomes difficult.
d) Dizziness or other distress occurs.
e) You taste or smell contaminants or an irritation occurs.
Never modify or alter this product, replace parts only with original 3M parts.
When using standard 4 and 8 hr batteries - Do not use in potentially flammable or explosive atmospheres.
When using I.S. battery and I.S. pouch and an appropriate headtop (Please see Jupiter™ Reference leaflet), use is permitted in
Potentially Explosive Atmosphere (Gases and Vapours) Zones 1 and 2, and (Dusts) Zones 21 and 22.
Do not use in Potentially Explosive Atmosphere Zones 0 and 20.
Do not use for mining applications.
09:05
Page 5
GB
5
Materials which may come into contact with the wearers skin are not known to cause allergic reactions to the majority
IRL
of individuals.
This product contains no components made from natural rubber latex.
EQUIPMENT MARKING
For headtop or facemask marking please see appropriate headtop User Instruction.
For filter marking please see appropriate filter User Instruction.
The Jupiter™ Air Filter unit is marked to EN12941.
The Jupiter™ Air Filter unit is marked with a date of manufacture. (month/year).
The Jupiter™ Air Filter unit is marked with IP53. (IP63 when fitted with I.S. pouch).
The Jupiter™ I.S. Pouch is marked with EN50014, EN50020 EEx ib IIB T3, EN50281, II 2 G D and SIRA Ex02Y2162X.
The Jupiter™ I.S. battery is marked to EN12941 and with, EN50014, EN50020 EEx ib IIB T3, EN50281, II 2 G D and SIRA
Ex02Y2162X.
The Jupiter™ 4hr and 8hr batteries are marked to EN12941.
PREPARATION FOR USE
Check:
Apparatus is complete, undamaged and correctly assembled, any damaged or defective parts must be replaced before use.
Undertake pre-use checks on headtop assembly as outlined in the appropriate user instruction.
For before use checks for I.S. pouch see 085-11-00P/085-12-00P User Instructions.
Fit the belt to the Air Filter Unit as outlined in the 022-25-03P/BLT-12 user instructions.
Select an approved battery (Please see Jupiter™ Reference leaflet for list of 3M approved batteries) charge as shown in Fig 1 and fit
as shown in Fig 2.
For use in Potentially Explosive Atmospheres, I.S. Battery pack and I.S. pouch must be fitted.
For fitting of the pouch see 085-11-00P/085-12-00P User Instructions.
Battery charging
The battery should be charged prior to first use or if unused for more than 5 days.
For charging of the 4 hr, 8hr and I.S. batteries please see Reference leaflet.
Note: The battery must be charged in a safe area.
Calibration
Calibrate the Air Filter Unit before first use and at least monthly thereafter. See Fig 3.
CALIBRATION
ENTERING CALIBRATION MODE
Hold switch button for 3 seconds, second
beep will sound, keep pressed during
calibration.
Display flashes fast during Calibration.
Fan will increase speed.
Release switch when ball is above mark.
(Fig 3).
Key
= Slow Flash
= Fast Flash
Filters
Select approved filters (Please see Jupiter™ Reference leaflet for list of 3M approved filters). Fit pre-filters (Fig 4) and then fit
filters as shown in Fig 5.
Air flow check
Before use, undertake air flow check using the air flow indicator tube (white ball). See Fig 6.
To check for correct functioning of audible warning device please see Fig 7.
OPERATING INSTRUCTIONS
Donning
1. Select an approved breathing tube (Please see Jupiter™ Reference leaflet for list of 3M approved breathing tubes) and connect
top end to the headtop assembly.
2. Adjust and buckle the waist belt with the Jupiter™ unit fitted comfortably around your waist and connect the bottom end of the
breathing tube to the outlet of the unit.
3. Adjust the headtop as outlined in the appropriate User Instruction.
4. Switch on the unit, fit the headtop and ensure at least minimum airflow is achieved. (The audible alarm will sound if below
minimum airflow – please see fault finding).
COMMENTS
DISPLAY
Please note:
Calibration should be
undertaken without
filters fitted, using a
After 3 seconds
fully charged battery,
and the calibration
tube (black ball).
= One Short Beep
6
SOUNDER
+