14. Niche dimensions
Dimensions in mm
15. Technical data
Operating conditions
Operating temperature
Relative air humidity
Storage temperature in preserved condition > -10 °C
Threshold values for the mains water
Water inlet temperature
Water hardness (total hardness level)
Minimum flow pressure
Maximum inlet pressure
Flow rate
Electrical conductivity (at 25° C)
Chlorine
Silicates (as SiO
)
2
If the water hardness level exceeds 3 °dH (0.5 mmol/l) we recommend the use of a water softening unit to
improve the performance of the reversis osmosis module. Moreover, the machine may develop limescale
deposits if the WaterEco function ( 4.2) is used frequently.
Total connected loads
Voltage
380 V–415 V / 3N~
380 V–415 V / 3N~
220 V–240 V / 1N~
220 V–240 V / 1N~
220 V–240 V / 1N~
220 V–230 V / 1N~
380 V–415 V / 3N~ *1
380 V–415 V / 3N~ *1
220 V–240 V / 1N~ *1
220 V–240 V / 1N~ *1
200 V / 3~
200 V / 2~
230 V / 3~
230 V / 2~
*1) Australia
0–40 °C
< 95 %
max. 35 °C
 35 °dH (43.9 °e; 62.3 °TH; 6.3 mmol/l)
140 kPa (1.4 bar)
600 kPa (6.0 bar)
at least 4 l/min
< 1200 µS/cm
< 0.2 mg/l
< 30 mg/l
Fuse protection
Total connected load
maximum
16 A
8.1 kW
10 A
6.2 kW
16 A
3.4 kW
20 A
4.4 kW
13 A
2.8 kW
10 A
2.0 kW
20 A
9.9 kW
15 A
7.9 kW
20 A
4.3 kW
15 A
3.1 kW
25 A
7.1 kW
20 A
3.5 kW
25 A
7.5 kW
16 A
3.2 kW
PG 8164 AE RO, AE RO DOS
+35
A
820
B
460
C
603
D
825-855
E
470-480
F
605
The machine can also be installed without feet. How-
ever, it can then no longer be adjusted.
Height of the machine without feet: 810
PG 8165 AE RO, AE RO DOS
+35
A
820
B
600
C
603
D
825-855
E
610-620
F
605
+5
mm
11
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pg 8164 ae ro dosPg 8165 ae roPg 8165 ae ro dos

Tabla de contenido