Connecting The Pipes; Attaching The Flue Duct - Gaggenau AW 250 Instrucciones De Uso Y Montaje

Ocultar thumbs Ver también para AW 250:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 72
Securing the appliance
1
Press the safety caps with the arrow upwards
onto the brackets until they engage.
2
Screw on the knurled nut and washer firmly.
Removing the safety caps
If the safety caps must be removed, use a flat
screwdriver.

Connecting the pipes

Note: If using an aluminium pipe, smooth the
connection area beforehand.
Exhaust-air pipe Ø 150 mm (recommended size)
Attach the exhaust-air pipe directly to the air-pipe
connector and seal.
Exhaust-air pipe Ø 120 mm
1
Attach the reducing connector directly to the air-
pipe connector.
2
Attach the exhaust air pipe to the reducing
connector.
3
Seal both joints appropriately.

Attaching the flue duct

m
®
Risk of injury!
¯
From sharp edges during installation. Always wear
protective gloves while installing the appliance.
1
Separate the flue ducts.
To do this, remove the adhesive tape.
2
Remove the protective foil from both flue ducts.
3
Push one flue duct into the other.
Notes
‒ To prevent scratches, lay paper over the edges
‒ Slots of the inner flue duct point downwards.
4
Place flue ducts on the appliance.
5
Push the inner flue duct upwards and attach it to
the fixing brackets on the left and right.
6
Press the flue duct downwards until it engages.
©
7
Screw the flue duct to the sides of the fixing
bracket using two screws.
of the lower flue duct to protect the surface.
¨
ª